Potentiometers P1 - P6

Refer to Figure 4-1 for location of potentiometers.
ACCEL time − P1
The time required to reach the Maximum Frequency setting of P4.
Accelerates at a linear rate.
First half (0 to 135° )= 0.1 sec to 10 sec
last half (135 - 270°) =10sec to 60 sec
DECEL time − P2
The time required to ramp to a stop. Decelerates at a linear rate.
First half (0 to 135° )= 0.1 sec to 10 sec
last half (135 - 265°) =10 sec to 60 sec
(265 - 270°) = Coast - Allows motor to coast to stop.
Minimum frequency − P3
Sets the minimum output frequency to the motor . This is a
percentage of the S1-1 base frequency setting.
Maximum frequency − P4
Sets the maximum output frequency to the motor. This is a
percentage of the S1-2 frequency limit setting.
Current Limit − P5
50% to 100% of control rated amps (see output current rating in
Section 6).
Torque Boost − P6
Increases the nominal motor starting voltage from 0 to 15% to
increase starting torque.
MN715P
(270° of rotation)
10 Sec.
60 Sec.
0.1 Sec.
10 Sec.
0.1 Sec.
1
/
0
2
1
/
LIM
2
50%
0%
Setup and Operation 4-4
60
Sec.
Coast
F
Base
LIM
100%
15%