Operation Examples

Operating the Control from the Front Panel
To place the control in local speed and command mode, place S1-7 and S1-8
in the OFF position. Refer to Figure 4-1 for switch location.
S1
Pos.
Position and Description
7
OFF
Local Speed Reference (front panel potentiometer)
8
OFF
Local command input (front panel FWD, REV, STOP)
The control can operate as follows:
1.
Set the P1 through P6 potentiometers as desired.
2.
Set switches S1-1, S1-2, S1-3 and S1-4 as desired.
3.
Adjust the motor's speed using the potentiometer on the front panel.
4.
Press the FWD or REV keys on the front panel.
5.
Press STOP on the front panel to stop motor rotation.
Note: S1-7 and S1-8 can be set so that either or both can be local or remote
inputs. The front panel potentiometer can be used with remote command
inputs by placing S1-7 OFF and S1-8 ON. Also, a remote speed reference
can be used while the front panel switches are used by placing S1-7 ON and
S1-8 OFF.
Speed Adjustment using a Remote Speed Reference
To use an external potentiometer or other signal source, refer to Figures 4-2,
4-3 and 4-4.
Figure 4-2 Remote Potentiometer 2 Wire Operation
S1 Pos.
Description
5
OFF
2 Wire
6
OFF
Voltage mode
7
ON
Remote Speed Ref.
8
ON
Remote commands
1.
2.
3.
4.
5.
4-5 Setup and Operation
Table 4-1 Active Switches for Local Operation
Set the P1 through P6 potentiometers as desired.
Set switches S1-1, S1-2, S1-3 and S1-4 as desired.
Close the FWD or REV key (both Open = Stop).
Adjust the motor's speed using the potentiometer at
J4-2.
Press STOP on the front panel to stop motor rotation.
J4
1
GND
2
Speed Command
+10VDC
3
4
Forward
5
Reverse
Not Used
6
MN715P