WARNING: CALIFORNIA PROPOSITION 65 WARNING: Engine exhaust from this product contains chemicals known to the state of California to cause cancer, birth defects and other reproductive harm. WARNING: CALIFORNIA PROPOSITION 65 WARNING: Battery posts, terminals and related accessories are known to the state of California to cause cancer, birth defects and other reproductive harm.
Section 1 Product Safety Information Safety Notice Be sure that you are completely familiar with the safe operation of this equipment. This equipment may be connected to other machines that have rotating parts or parts that are controlled by this equipment. Improper use can cause serious or fatal injury. Always disconnect all electrical loads before starting the generator.
Precaution Statements Used In This Manual There are three classifications of precautionary statements used in this manual. The most critical is a WARNING statement, then the Caution statement and the least critical is the Note statement. The usage of each statement is as follows: WARNING: Indicates a potentially hazardous situation which, if not avoided, could result in injury or death.
Page 7
Operation Warning Statements Continued WARNING: Be sure that you understand how to stop the engine quickly in case of an emergency situation. Become familiar with the controls and safety systems provided with this generator set. WARNING: Always wear safety glasses with side shields and hearing protection when working near the generator.
Page 8
Warning Statements Continued Burn WARNING: Parts of this generator are extremely hot during and after operation. To prevent severe burns, do not touch any part of the generator until you have first determined if the part is hot. Wear protective clothing and after use allow sufficient time for parts to cool before touching any part of the generator.
Warning Statements Continued Maintenance WARNING: Before servicing the generator set, be sure to disconnect the spark plug(s) to prevent accidental engine starting. WARNING: Before cleaning, inspecting, repairing, refueling or performing any maintenance to the generator set, always be sure the engine has stopped and that all rotating parts have also stopped.
Limited Warranty Baldor will replace or repair free of charge any part or parts of the generator of their manufacture that are defective in workmanship and materials for a period of time as set forth in the Warranty Period chart below. All Baldor products requiring warranty service shall be transported or shipped freight pre-paid to a Baldor Generator repair facility.
Section 3 Receiving & Installation Receiving & Inspection When you receive your generator, there are several things you should do immediately. Observe the condition of the shipping container and report any damage immediately to the commercial carrier that delivered your system. Verify that the part number of the system you received is the same as the part number listed on your purchase order.
Physical Location The mounting location of the system is important. It should be installed in an area that is protected from direct harmful gases or liquids, dust, metallic particles, shock and vibration. It can only be installed in an outdoor location so the exhaust fumes are vented to the atmosphere. This system must never be installed inside an enclosed building, home, shop or garage etc.
Page 15
Electrical Connections All load connections are made at the panel using electrical cords with the proper mating plug for the receptacle being used. More than one receptacle can be used as long as the total load does not exceed the continuous rating of the generator. WARNING: Never connect this generator to any buildings electrical system unless a licensed electrician has installed an approved transfer switch.
Frame Ground Connection WARNING: Be sure the system is properly grounded before applying power. Do not apply AC power before you ensure that grounds are connected. Electrical shock can cause serious or fatal injury. NEC requires that the frame and exposed conductive surfaces (metal parts) be connected to an approved earth ground.
Section 4 Operation Operator Control Panel The Operator Panel is shown in Figure 4‐1. Figure 4‐1 Operator Panels AC Circuit Breakers 120VAC 120VAC 240VAC WARNING: Never connect this generator to any buildings electrical system unless a licensed electrician has installed an approved transfer switch. The National Electrical Code (NEC) requires that connection of a generator to any electrical circuit normally powered by means of an electric utility must be connected by means of approved transfer switch equipment so as to isolate the electrical circuit from the utility distribution system when the generator is operating.
Start-Up Procedure Recoil Start Move the engine's choke lever to the “Choke/Start” position. If the engine is warm or if the ambient air temperature is high; try starting the engine without choking it. Move the Control Panel Engine “ON/OFF” switch to “ON” (if equipped). Pull lightly on the recoil grip until you feel significant resistance, then pull sharply.
Section 5 Troubleshooting and Maintenance Maintenance This manual contains only very minimal engine maintenance instructions. Refer to the engine manufacturer's owner's manual for specific engine maintenance instructions for your generator set. Any maintenance instructions or recommendations in the engine owner's manual take precedence over any of the following general recommendations.
Problems and Solutions Some of the more common problems are listed in Table 5‐1. This information is intended to be a check or verification that simple causes can be located and fixed. It is not an exhaustive “how to” for all types of problems. Procedures that require in depth knowledge or skills (like flashing the field) should be referred to generator service facility.
Appendix A PG6000 Connections Caution: The brass connecting tab on some 120VAC duplex receptacles has been removed. Each receptacle is powered by a separate generator winding. When replacing a receptacle, inspect the brass tab that normally links both receptacles. If it is removed, be sure to remove the brass tab from the replacement receptacle before it is installed.
CARB EECS regulations; (2) free from defects in materials and workmanship that cause the failure of a warranted part to be identical in all material respects to that part as described in Baldor's application of certification to CARB; (3) the warranty period begins on the date the generator is delivered to an ultimate purchaser or first placed into service.
Page 24
WARNING: CALIFORNIA PROPOSITION 65 WARNING: Engine exhaust from this product contains chemicals known to the state of California to cause cancer, birth defects and other reproductive harm. WARNING: CALIFORNIA PROPOSITION 65 WARNING: Battery posts, terminals and related accessories are known to the state of California to cause cancer, birth defects and other reproductive harm.