Furuno FSV-84 Installation Manual page 64

Color scanning sonar
Hide thumbs Also See for FSV-84:
Table of Contents

Advertisement

3. Fix the power supply pcb (supplied) to the power module with four spacers (supplied).
4. Connect two VH connectors (provided on the power module) to the power supply pcb.
5. Lay the protection sheet (supplied) on top of the spacers and fasten with pan head
screws (M3×8).
6. Reattach the power module.
7. Connect between the processor unit and CS-120A as follows.
PROCESSOR
UNIT
OR NMEA2/CIF2
CIF_TXD_H
CIF_TXD_C
CIF_RXD_H
CIF_RXD_C
SHIELD
For CIF1
GND
For CIF2
8. Set the DIP switch on the DCON Board as follows.
Input port
CIF1
NMEA2/CIF2
For connection to NMEA2/CIF2 port, the #8 segment of S2 on the IFES board should be
OFF (CIF).
Note: If the CIF1 format is selected, change baud rate to 2400 bps. See CIF BAUD RATE
on page 3-8 for details.
4-2
MJ-A3SPF0013-035
CS-120A
+24V_H
1
+24V_C
2
GND
3
1
2
3
4
5
6
37-core cable
10S1258
Wiring between processor unit and CS-120A
DIP switch setting on DCON Board
S3-#2: ON
S3-#3: ON
DCON Board (10P6987)
YEL
BRN
L
ORG
BRN
E
PPL BRN
PP
NN
MM
JJ
KK
BB
EE
DD
Z
S3
CS-120A
J201
24V
0V
GND
TD-H
TD-C
RD-H
RD-C
GND
DSR-C
DSR-H
DTR-H

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents