Monitor Unit (Option) - Furuno FSV-84 Installation Manual

Color scanning sonar
Hide thumbs Also See for FSV-84:
Table of Contents

Advertisement

2.3 Monitor Unit (option)

2.3.1 Fabrication of cable from processor unit
One of the cables 10S2074 (10 m) or 10S2075 (30 m) runs between the processor unit
(FSV-8402) and the monitor unit (FSV-2400). Pass it through the cable clamp at the rear of
the monitor unit and connect.
SHIELD
11 12
30
29
28
1
10
2
27
9
26
8
25
7
5
6
24
23
20
22
21
Fabrication of 38P connector 00-8016-038-313761HV (CN-A303)
Fabrication of cable for 38P connector 00-8016-038-313761HV
2-4
ANTICORROSIVE SHEATH
1. GRY (No.1)
13
2. BLK/WHT
14
15
3. GRY (No.2)
3
16
4. BLK/RED
4
17
5. GRY (No.3)
18
6. BLK/GRN
19
7. GRY (No.4)
8. BLK/YEL
ARMOR
1, 3, 5. 7, 9: Coaxial cables
Others:
Cable 10S2074, sectional view
250
45
Shield
40
Vinyl Sheath
Armor
Core
After exposing cores,
wind shield around the armor.
Assembling 38P connector
9. GRY (No.5)
10. BLK/BLU
11. BLK/BRN
12. BLK/PPL
13. WHT/RED
14. WHT/GRN
15. WHT/YEL
16. WHT/BLU
Twisted pair cables
Anticorrosive
Sheath
Insulating Tape
Guide Pin A
Position No.
Guide Pin A
(Large)
17. WHT/BRN
25. GRN/BLU
18. WHT/PPL
26. GRN/BRN
19. RED/GRN
27. GRN/PPL
20. RED/YEL
28. YEL/BLU
21. RED/BLU
29. YEL/BRN
22. RED/BRN
30. YEL/PPL
23. RED/PPL
24. GRN/YEL
Guide Pin B
Guide Pin B
(Small)