2.7 Input Voltage and Fuses

The transceiver unit is shipped from the factory with its input voltage set for 230 VAC and a
10 A fuse inserted in F601 and F602. For other voltages, change toggle switch positions and
fuses as below.
Input voltage
Set the toggle switches S603, S604 and S605 according to input voltage, referring to the
table below.
Input
S603
(TB-B101)
100 VAC
L
110 VAC
H
115 VAC
H
220 VAC
H
230 VAC
H
Fuses
Change the fuse in F601 and F602 according to input voltage, referring to the table below.
Input
(TB-B101)
F601
100 VAC
20A
110 VAC
115 VAC
220 VAC
10A
230 VAC
Marking the label
After setting toggle switches and changing the fuses,
mark the label on the inside of the cover with the
voltage that applies. In the example shown right, 100
V is marked so 20A fuses must be used.
2-18
S604
S605
L
L
L
L
H
L
L
H
H
H
Fuse
Default
setting
F602
20A
Default
10A
setting
Default setting
Default setting
WARNING
Use the proper fuse.
Use of a wrong fuse can result in damage
to the equipment or cause fire.
FUSE
F601
INPUT
(TB-B101)
FUSE
F602
FUSE
F601
F602
100V
110V
20A
20A
115V
220V
10A
10A
230V