Operating conditions

Feeding current
PV array voltage
Daily Energy
System Fault
Isolation failure
GFCI active
Grid failure
No utility
Input voltage too high
Inverter Fault
Consistent failure
Temperature too high
Output relay failure
Output DC injection too high
EEPROM problem
Communication failure
between microprocessors
25
In English
Iac = x.xA
Vdc = xxx.x V
Etoday=xxx.xxKW
h
Isolation fault
Ground I fault
Grid fault
No Utility
Input voltage is higher than the maximum
PV over voltage
The readings of 2 microprocessors are not
Consistent Fault
Over temperature
The relay between inverter and grid is not
Relay Failure
DC INJ High
EEPROM Failure EEPROM inside has data access problem
The communication between MCU inside
SCI Failure
Description
Feeding current amount in xx.x A
Input voltage from PV array, xxx.x VDC
The accumulated kWh of that day
Earth fault of the PV-panels or failure of
surge voltage protection
Leakage current detected from ground
conductor is too high
Grid measured data is beyond the
specification (voltage & frequency)
Utility is not available
input voltage
consistent. It could be caused by CPU
and/or other circuit do not function well.
The internal temperature of inverter is
higher than normal value
functional
Output DC injection is higher than
expected
is abnormal