5.1. Inspect after Opening

Please first check if the models and part numbers are in consistence, and also check if the
equipments are damaged.

5.2. Preparation before Installation

Carefully read this manual
Prepare all kinds of the cable. Ensure that they are not short-circuited. Refer to Appendix A for cable
making.
Ensure the voltage of power supply is in the tolerance range, the chassis is well connected with the
ground.
Prepare the BERT and optical power meter for test of line quality.
Place the equipment at stable and secure environment. Pay attention to the requirements of the
ambience.

5.3. Installation

5.3.1. Connecting the Cables

V.35 Interface
This interface is not hot-swappable. Please connect it properly before applying the power supply.
Ethernet Interface
Connect with Cat. 5 or hyper Cat. 5 twisted-pair cables. Either straight-through or crossover cable is
OK.
Fiber connector
Plug the tail fiber into the fiber socket to the end.

5.3.2. Applying the Power Supply

The power supply shall be applied after the previous operation.
If using DC -48V power supply, please first connect "ground" cable with protecting ground. "0V" pin
shall be connected with high potential cable, "-48V' pin shall be connected with low potential cable.
Ensure there is no short circuit.
If using AC 220V power supply, please use the power cable supplied along with equipment.
After applying the power supply, PWR indicator shall be on.