CONVERSION TO A DIFFERENT TYPE OF
GAS
Before converting the appliance for operation with
a different gas type, check which type of gas it is
currently set to operate with (adhesive label 1 on
appliance).
For the correct nozzle diameter, refer to the
relative table in this booklet.
Conversion to a different gas type must be carried
out by qualified technicians and in conformance
with the requirements.
Conversion procedure:
x
Disconnect the electrical power supply to
the appliance,
x
Change the main oven nozzle:
1. Remove the burner cover plate (see
«Removal of the burner cover plate»),
2. Remove the screw securing the oven
burner 2 and with draw the burner from the
support together with the heat sensor and
the ignition spark plug,
3. Remove the nozzle using a 7 mm box
wrench 3,
4. Screw the new nozzle in fully (diameter in
hundredths of millimetre stamped on the
nozzle), taking care not to cross the thread,
5. Replace
the
operations in step 2 above,
6. Replace the cover plate.
NOZZLE TABLE
The diameters in hundredths of millimetre are
stamped on the nozzle.
Rated load
Burner
kW
Oven
2,50
burner
Grill
2,20
burner
EN
burner
reversing
Nozzle bore in mm
G20/20
G30/29
1,13
0,76
1,12
0,75