Vemer Dafne User Manual page 39

Digital programmable thermostat
Hide thumbs Also See for Dafne:
Table of Contents

Advertisement

(activation time + deactivation time of heating) and it can have values of 10, 20 or
30 minutes.
During the operating, at the beginning of the regulation period, the instrument
measures the environment temperature and it compares it with the programmed
setpoint; on the basis of this difference the activation time is calculated (and
setpoint value – band, the more the activation time will be predominant in comparison
with the deactivation time; on the contrary, the more the measured temperature is next
to the setpoint value + band, the more the deactivation time will be predominant in
comparison with the activation time).
Once regulation period is passed, the instrument compares again the environment
temperature with the setpoint and it updates the activation and deactivation times for
the new period.
The result of the proportional regulation is subordinated to the correct selection of the
parameters.
Select the value of the regulation type as follows:
Select the regulation band value as follows:
To modify the regulation type, the differential value (on/off regulation), band
To modify the regulation type, the differential value (on/off regulation), band
and period (proportional regulation) see chapter "Regulation parameters" on
and period (proportional regulation) see chapter "Regulation parameters" on
page 29.
page 29.
- 37 -
Dafne programmable thermostat, user's manual