Vemer Athena Silver User Manual

Vemer Athena Silver User Manual

Programmable digital thermostat multizone / wireless, white/silver

Advertisement

Quick Links

Cronotermostato
Digitale
Athena
Manuale d'uso
User Manual
PROGRAMMABLE DIGITAL THERMOSTAT

Advertisement

Table of Contents
loading

Summary of Contents for Vemer Athena Silver

  • Page 1 Cronotermostato Digitale Athena Manuale d’uso User Manual PROGRAMMABLE DIGITAL THERMOSTAT...
  • Page 3: Table Of Contents

    Index Safety Instructions Page Technical Specifications Page Description Page Programming Page Switch-on Reset Page Setting The Time Page Operating Modes Page Programming Menu Page Control by telephone dialler Page Network Configuration Page Error Messages Page Reference Standards Page Dimensions Page Wiring Diagram Page Installation And Battery Placing...
  • Page 4: Safety Instructions

    Color VN940300 Athena Programmable digital thermostat multizone/wireless White VE080800 Athena Silver Programmable digital thermostat multizone/wireless Silver TECHNICAL SPECIFICATIONS • Power supply voltage: 2x1,5V (AAA) alkaline batteries • Battery autonomy: 12 months approx. • Standby battery: approx. 2 minutes for battery replacement •...
  • Page 5: Description

    • Storage Temperature: -10°C ÷ 65°C • LCD display reading the temperature, time, date and daily program • Protection degree: IP40 DESCRIPTION LCD DISPLAY, KEYPAD 11 12 13 14 15 16 17 18 19 20 21 22 23 Figure 1 The LCD display reads the following information (Figure 1): 1 Graph of selected temperatures 2 Actuator ON in winter operation mode...
  • Page 6: Programming

    14 Zone name, external temperature, or manual temperature reading 15 Measured temperature 16 Temperature measurement or acquisition in process 17 Unit of measurement °C/F 18 Manual operation 19 Wireless card IN 20 Extension program enabled 21 Telephone dialler status Keypad (Figure 2): •...
  • Page 7: Operating Modes

    ° GG.MM.AAAA • To end and save the changes press the [OK] key. • Press to exit the time setting page. • The programmable thermostat will then start to control the temperature automatically according to program P00 for weekdays, from Monday to Friday, and program P01 for Saturdays and Sundays.
  • Page 8 • When on the main page, it is possible to view more details about the current zone . If key is pressed when on field 14 (see Figure 1), the using keys current zone name will appear (if it was entered; otherwise the reading “zona…” will appear).
  • Page 9: Programming Menu

    COUNTDOWN PROGRAM • By the countdown program it is possible to schedule system switch-on and switch-off on a certain date. • As for details on configuring the countdown program, refer to the "Timer programming" section on page 36. NOTE: the countdown program cannot be enabled if the extension program is already enabled.
  • Page 10 • To change parameter status, press [OK], make your selection using keys and confirm by the [OK] key. • The time changing date and hour cannot be altered: ° winter summer change: last Sunday in March, at 02:00 ° summer winter change last Sunday in October, at 03:00 DAILY PROGRAMMING...
  • Page 11 Changing daily program • After pressing the [OK] key, the temperature bar corresponding to the current time will start to flash. The display reads the programming time and the current temperature selection (T0, T1, T2 or T3). 11 12 13 14 15 16 17 18 19 20 21 22 23 11 12 13 14 15 16 17 18 19 20 21 22 23 11 12...
  • Page 12 11 12 13 14 15 16 17 18 19 20 21 22 23 11 12 13 14 15 16 17 18 19 20 21 22 23 11 12 13 14 15 16 17 18 19 20 21 22 23 PRE-SET SUMMER PROGRAMS 11 12 13 14 15 16 17 18 19 20 21 22 23 11 12...
  • Page 13 11 12 13 14 15 16 17 18 19 20 21 22 23 11 12 13 14 15 16 17 18 19 20 21 22 23 TEMPERATURE PROGRAMMING • Temperature control uses 4 independent setpoint levels for each control zone and for summer and winter operation modes.
  • Page 14 TIMER PROGRAMMING • • In this menu it is possible to determine system switch off/switch on parameters (countdown), and view the system's work hour-count for the current zone • When system switch-on is scheduled, all the zones will be put "off" until the scheduled date;...
  • Page 15 ZONE-CONTROL PARAMETER PROGRAMMING MENU • In this menu, which is marked by symbol , it is possible to configure the control parameters for the currently displayed zone: ° winter/summer operation mode (winter by default); ° temperature-control type (ON/OFF or proportional) (ON/OFF by default);...
  • Page 16 • If an operation setting is changed, temperature control will be ON-OFF type until Tset is reached for the first time; this will help reaching the selected conditions more quickly. IMPORTANT: PROPORTIONAL mode selection has no effect on summer operation. Temperature control is always ON/OFF type in summer operation mode.
  • Page 17 • Press [OK] to enter the parameter changing page. The parameter that can be changed is the intermittent one. • Select the parameter to be changed using arrows ; modify the parameter . Press [OK] ] to end the change and configure the associated using arrows devices.
  • Page 18 Standard zone configuration: zone n° description probe actuator ZONE 1 built-in relay ZONE 2 ZONE 3 ZONE 4 External probe • From the configuration menu for zone 4, press key view the external probe menu. • This is used to configure an external temperature probe (optional).
  • Page 19 • This menu, marked by the symbol, reads the battery level (in percentage). • When the batteries are running down, the symbol appears on the main page too. The device keeps on performing all functions, although displaying the reminder that batteries need to be replaced shortly. WARNING: operation on low batteries does not guarantee relay switching, wireless transmission or bus communication.
  • Page 20: Control By Telephone Dialler

    CONTROL BY TELEPHONE DIALLER Athena has got an input for the connection to a clean contact to whom to connect for example a telephone dialler to switch on or to switch off remotely the programmable thermostat with their own telephone. The contact can have one of these two positions: - open = normal operation (according to the settings) - closed = programmable thermostat in off mode.
  • Page 21: Reference Standards

    REFERENCE STANDARDS Conformity to the EU directives: 2006/95/EC (Low Voltage) 2004/108/EC (Electromagnetic Compatibility) is declared with reference to the following harmonized standards: EN 60730-2-7, EN 60730-2-9 EN 61000-6-1, EN 61000-6-3 - 41 - User Manual Athena...
  • Page 22: Dimensions

    DIMENSIONS WIRING DIAGRAM External communication probe Telephone dialler - 42 - User Manual Athena...
  • Page 23: Installation And Battery Placing

    INSTALLATION AND BATTERY PLACING - 43 - User Manual Athena...
  • Page 24 Vemer S.p.A. I - 32032 Feltre (BL) • Via Camp Lonc, 16 Tel +39 0439 80638 • Fax +39 0439 80619 e-mail: info@vemer.it - web site: www.vemer.it...