Check
Marked Copies
Is the machine's Platen Glass or Platen Sheet
dirty?
Is the original an OHP film or a dark original?
If a dark verical line of
2-3cm in width is printed.
■ If the measures outlined above do not solve the problem, call your Service provider.
Adjusting the Double Feed Switch (For DA-AS181)
■ When original(s) do not feed correctly, adjust the position of
the Double Feed Switch as follows:
Double Feed Switch

Machine Care

■ As a rule, clean weekly.
Platen Sheet
Clean the Platen Glass or Sheet.
Cover the original with a sheet of white paper
before copying or lighten the exposure setting.
Clean the Corona Wire of the Drum Unit.
(See page 16)
Check the copies.
If a dark vertical line is remained, repeat
above step to clean the Corona Wire
became dark vertical line is erased.
Normal Operation
Original does not feed.
Several originals are fed
at one time
Platen Glass/Platen Sheet
Wipe marks off with a cloth and a neutral detergent.
Wipe again with a dry cloth.
Platen (Glass)
Action
Position of
Switch
69