Alarm Control Functions; Alarm Input; Alarm Operation; Alarm Reset - Panasonic WJ-MP204 Operating Instructions Manual

Data multiplex unit
Hide thumbs Also See for WJ-MP204:
Table of Contents

Advertisement

ALARM CONTROL FUNCTIONS

Alarm Input

The Data Multiplex Unit processes the following alarms.
(As to setting, see page 14, 18 and 19.)
• Camera Site Alarm
Alarm multiplexed with video signals from the camera.
• Terminal Alarm
Alarm received from the ALARM/REMOTE connector.

Alarm Operation

ALARM MODE set to ON on the Setup menu (See pages
14 and 18 for details.)
• Alarm indicator blinks.
• Alarm data is transmitted to the system controller and
other system units.
MONITOR SPOT set to ON on the Setup menu (See pages
14 and 18 for details.)
• The camera pictures change automatically to the spot
where the alarm is activated.
• The camera pictures change to the preset position
when the alarm is activated in Panasonic Security Data
mode.
ALARM DISPLAY set to ON on the Setup menu (See pages
14 and 18.)
• [ALARM
] appears on the screen. [ALARM
blinks in alarm ON mode.
Note: The figure shown in the place of [
word ALARM is a channel number.
ALARM OUTPUT set to EXT or 1S-5MIN on the Setup menu
(See pages 14 and 18.)
• Alarm signal is supplied from the alarm output connec-
tor. This permits controlling external devices in case of
an alarm.
• Camera site alarm is available to each channel.
Each alarm signal can be supplied independently from
ALARM/REMOTE connector by shifting the internal con-
nector.
28
] after the
ALARM 001

Alarm Reset

Mode After Alarm Reset
• The camera picture remains as it is until the alarm is
reset.
• [ALARM
] disappears. The figure shown in the place
of [
] after the word ALARM is a camera number.
• Alarm signal output stops.
• The alarm indicator stops blinking.
• Reset signal is supplied from the alarm reset output.
Manual Reset
The following are the steps to reset the alarm.
• Press the ALARM RESET button on the System
Controller WV-CU360.
mode only)
• Press the ALARM RESET button on the WJ-MP204.
• Signal is sent to the alarm recover input connector.
• Alarm reset command is sent to the RS-485 terminal (in
camera communication mode only).
Auto Reset
An alarm is automatically reset when the programmed
alarm output time is over. The alarm indicator changes from
blinking to steady light (See pages 14 and 18).
Note: To go the alarm indicator off, take any one of the
steps for manual reset.
]

Alarm Suspend

Alarms will be ignored when the ALARM/SUSPEND button
is pressed. The alarm suspension mode is reset when the
ALARM/SUSPEND button is pressed again. The alarm sus-
pend indicator remains lighted during alarm suspend
mode.