• Alarm Data
This is to set whether or not the alarm data received
from a camera is to be transmitted to the WV-CU360.
POLLING: Disables to transmit to the system controller
even if an alarm is activated.
AUTO1: Enables to transmit to the system controller
when an alarm is activated.
AUTO2: Enables to transmit to the system controller
when an alarm is activated. Ignores an alarm for 5
seconds after it has transmitted. Enable to transmit
an alarm after it has elapsed for 5 seconds.
1. Display the SYSTEM menu.
2. Move the cursor to ALARM DATA by pressing button 1
(C) or button 2 (D), then select the desired alarm data
mode, POLLING, AUTO1, or AUTO2, by pressing but-
ton 3 (–) or button 4 (+).
The initial factory setting is AUTO2.
(2) Comp/VD2/Data Setting
COMP/VD2/DATA
CAMERA IN 1CH
COMP
VD2
DATA
• Camera Input Setting
1. Display the SYSTEM menu.
2. Move the cursor to CAMERA IN by pressing button 1
(C) or button 2 (D), press the SUSPEND/SET button,
then select the desired channel 1, 2, 3 or 4 for back-
ground picture by pressing button 3 (–) or button 4 (+).
The initial factory setting is 1CH.
• Cable Compensation Setting
1. Display the SYSTEM menu.
2. Move the cursor to COMP by pressing button 1 (C) or
button 2 (D), press the SUSPEND/SET button, then
select the most suitable cable length by pressing but-
ton 3 (–) or button 4 (+).
S: Less than 400 m (1,300 ft)
M: 400 m (1,300 ft) to 700 m (2,300 ft)
L: 700 m (2,300 ft) to 900 m (3,000ft)
(When using RG-59U, BELDEN 9259 or equivalent
cable)
The initial factory setting is S.
• VD2 Setting
1. Display the SYSTEM menu.
2. Move the cursor to VD2 by pressing button 1 (C) or
button 2 (D), press the SUSPEND/SET button, then
select ON, OFF, or THROUGH by pressing button 3 (–)
or button 4 (+).
19
S
ON
ON
ON: Multiplex sync signals (VD2) are generated by syn-
chronizing with the signals sent to the VS/VD IN
connector. If there is no input signal, the internally
generated sync signal (VD2) is multiplexed.
OFF: Sync signal (VD2) is not multiplexed.
THRU: The sync signal (VD2) sent to the CAMERA OUT
connector is multiplexed with the video signals. If
there is no input signal, the sync signal (VD2) is not
multiplexed.
The initial factory setting is ON.
• Data Setting
1. Display the SYSTEM menu.
2. Move the cursor to DATA by pressing button 1 (C) or
button 2 (D), press the SUSPEND/SET button, then
select data communication ON or OFF by pressing but-
ton 3 (–) or button 4 (+).
The initial factory setting is ON.
(3) VS/VD Input
1. Display the SYSTEM menu.
2. Move the cursor to VS/VD INPUT by pressing button 1
(C) or button 2 (D), then select VS or VD by pressing
button 3 (–) or button 4 (+).
The initial factory setting is VD.
(4) Daisy Mode
1. Display the SYSTEM menu.
2. Move the cursor to DAISY MODE by pressing button 1
(C) or button 2 (D), then select control mode ON or
OFF by pressing button 3 (–) or button 4 (+).
The initial factory setting is ON.
(5) Terminal
1. Display the SYSTEM menu.
2. Move the cursor to TERMINAL by pressing button 1 (C)
or button 2 (D), then select ALARM or REMOTE by
pressing button 3 (–) or button 4 (+).
The initial factory setting is ALARM.
Note: To switch from ALARM/REMOTE IN to ALARM/
REMOTE OUT, shift the internal connector of the WJ-
MP204 from the ALM IN connector to the ALM OUT
connector (See page 24).
The initial factory setting of ALARM/REMOTE connector
is ALM IN.