System Setup for Camera
Communication Mode
1. Display the Setup menu.
2. Move the cursor to SYSTEM by pressing button 1 (C)
or button 2 (D), then press the SUSPEND/SET button.
• In case of Camera Communication mode, the SYS-
TEM menu appears as shown below.
ALARM MODE
COMP/VD2/DATA
VS/VD INPUT
DAISY MODE
TERMINAL
3. Move the cursor to the desired item by pressing button
1 (C) or button 2 (D), and then select the desired
mode by pressing button 3 (–) or button 4 (+).
4. Press the SUSPEND/SET button.
5. After taking the above steps, press the SETUP/ESC
button for 2 seconds or more.
Note: All the settings must be compatible with the
peripherals connected.
(1) Alarm Mode Setting
• Monitor Spot Setting
MONITOR SPOT
ALARM DISPLAY ON
SITE ALARM
TERM.ALARM
ALARM OUTPUT
ALARM DATA
1. Display the SYSTEM menu.
2. Move the cursor to ALARM MODE by pressing button 1
(C) or button 2 (D), press the SUSPEND/SET button,
then select MONITOR SPOT ON or OFF by pressing
button 3 (–) or button 4 (+).
The initial factory setting is ON.
ON: The screen of the corresponding channel appears
on the spot output screen when the alarm is activat-
ed.
OFF: The screen continues to display the pictures in
the mode selected previously when the alarm is
activated.
18
SYSTEM
ON
VD
ON
ALARM
ALARM MODE
ON
ON
ON
10S
AUTO2
• Alarm Display Setting
1. Display the SYSTEM menu.
2. Move the cursor to ALARM DISPLAY by pressing button
1 (C) or button 2 (D), then select ALARM DISPLAY ON
or OFF by pressing button 3 (–) or button 4 (+) so that
[ALARM
] appears on the screen or not.
The initial factory setting is ON.
Note: The figure shown in the place of [
word ALARM is a channel number.
• Site Alarm Setting
1. Display the SYSTEM menu.
2. Move the cursor to SITE ALARM by pressing button 1
(C) or button 2 (D), then select SITE ALARM ON or
OFF by pressing button 3 (–) or button 4 (+).
The initial factory setting is ON.
• Terminal Alarm Setting
1. Display the SYSTEM menu.
2. Move the cursor to TERM. ALARM by pressing button 1
(C) or button 2 (D), then select TERM. ALARM ON or
OFF by pressing button 3 (–) or button 4 (+).
The initial factory setting is ON.
• Alarm Output Data (Alarm Output Duration from
Alarm Connector)
1. Display the SYSTEM menu.
2. Move the cursor to ALARM OUTPUT by pressing button
1 (C) or button 2 (D), then select the desired alarm
output duration, 1S - 30S, 40S, 50S, 1MIN, 2MIN, 3MIN,
4MIN, 5MIN, EXT or OFF, by pressing button 3 (–) or
button 4 (+).
The initial factory setting is 10S. Enable to set by 1 sec-
ond (1S - 30S).
EXT:
The alarm signal continues to be output from
ALARM/REMOTE connector till the alarm is
reset. The alarm is not automatically reset.
1S-5MIN: The alarm signal is supplied from ALARM/
REMOTE connector only for the set time. The
alarm is automatically reset after the set time.
(The ALARM indicator changes from blink to
steady light.)
OFF:
The alarm signal is not supplied from ALARM/
REMOTE connector. The alarm is not auto-
matically reset.
] after the