Panasonic WJ-MP204 Operating Instructions Manual page 14

Data multiplex unit
Hide thumbs Also See for WJ-MP204:
Table of Contents

Advertisement

(1) Alarm Mode Setting
• Monitor Spot Setting
MONITOR SPOT
ALARM DISPLAY ON
SITE ALARM
TERM.ALARM
ALARM OUTPUT
ALARM DATA
1. Display the SYSTEM menu.
2. Move the cursor to ALARM MODE by pressing button 1
(C) or button 2 (D), press the SUSPEND/SET button,
then select MONITOR SPOT ON or OFF by pressing
button 3 (–) or button 4 (+).
The initial factory setting is ON.
ON: The screen of the corresponding channel appears
when the alarm is activated. If MONITOR SPOT ON
with the mark
as shown below.
ALARM
1
2
3
4
Enter each camera number and a preset position for
each alarm number. If the Data Multiplex Unit is con-
nected to a combination camera, enter a preset posi-
tion for the PRE parameter.
OFF: The screen continues to display the pictures in
the mode selected previously when the alarm is
activated.
For further information on preset positions, refer to the
Operating Instructions for the combination camera.
• Alarm Display Setting
1. Display the SYSTEM menu.
2. Move the cursor to ALARM DISPLAY by pressing button
1 (C) or button 2 (D), then select ALARM DISPLAY ON
or OFF by pressing button 3 (–) or button 4 (+) so that
[ALARM
] appears on the screen or not.
The initial factory setting is ON.
Note: The figure shown in the place of [
word ALARM is a channel number.
• Site Alarm Setting
1. Display the SYSTEM menu.
2. Move the cursor to SITE ALARM by pressing button 1
(C) or button 2 (D), then select SITE ALARM ON or
14
ALARM MODE
ON
ON
ON
10S
1S
is selected, the screen appears
MONITOR SPOT
CAM NO.
PRE
1CH
-
2CH
-
3CH
-
4CH
-
OFF by pressing button 3 (–) or button 4 (+).
The initial factory setting is ON.
• Terminal Alarm Setting
1. Display the SYSTEM menu.
2. Move the cursor to TERM. ALARM by pressing button 1
(C) or button 2 (D), then select TERM. ALARM ON or
OFF by pressing button 3 (–) or button 4 (+).
The initial factory setting is ON.
• Alarm Output Data (Alarm Output Duration from
Alarm Connector)
1. Display the SYSTEM menu.
2. Move the cursor to ALARM OUTPUT by pressing but-
ton 1 (C) or button 2 (D), then select the desired alarm
output duration, 1S - 30S, 40S, 50S, 1MIN, 2MIN, 3MIN,
4MIN, 5MIN, EXT or OFF, by pressing button 3 (–) or
button 4 (+).
The initial factory setting is 10S. Enable to set by 1 sec-
ond (1S - 30S).
EXT: The alarm signal continues to be output from
1S-5MIN: The alarm signal is supplied from ALARM/
OFF: The alarm signal is not supplied from ALARM/
• Alarm Data
This is to set whether or not the alarm data received
from a camera is to be transmitted to the WV-CU360.
OFF:
0S:
1S:
5S:
Note: To set 0S, 1S or 5S, the system controller set as
controller No. 1 must be connected to the system.
1. Display the SYSTEM menu.
] after the
2. Move the cursor to ALARM DATA by pressing button 1
(C) or button 2 (D), then select the desired alarm data
duration, OFF, 0S, 1S, or 5S, by pressing button 3 (–)
or button 4 (+).
The initial factory setting is 1S.
ALARM/REMOTE connector till the alarm is reset.
The alarm is not automatically reset.
REMOTE connector only for the set time. The
alarm is automatically reset after the set time.
(The ALARM indicator changes from blink to
steady light.)
REMOTE connector. The alarm is not automati-
cally reset.
Select this parameter if the system controller is
not connected to the system, or if operation is
to be controlled via an AV Codec.
Each time an alarm is detected, it is notified to
the system controller.
When an alarm is detected, it is notified to the
system controller. (Alarm data on each channel
where an alarm is detected is stored for 1 sec-
ond, and the stored alarm data is sent to the
system controller.)
When an alarm is detected, it is notified to the
system controller. (Alarm data on each channel
where an alarm is detected is stored for 5 sec-
onds, and the stored alarm data is sent to the
system controller.)