Electrical Connection - Maytag MEDX5SPAW0 Installation Instructions Manual

27" wide models
Hide thumbs Also See for MEDX5SPAW0:
Table of Contents

Advertisement

Available languages

Available languages

ELECTRICAL
Power Supply Cord
CONNECTION
Direct Wire
Fire Hazard
Use a new UL listed 30 amp power supply cord.
Use a UL listed strain relief.
Disconnect power before making electrical
connections.
Connect neutral wire (white or center wire) to center
terminal.
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining 2 supply wires to remaining
2 terminals
(gold).
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or
electrical shock.
Fire Hazard
Use 10 gauge copper wire.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal.
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining
2 supply wires to remaining
2 terminals
(gold).
Securely tighten
all electrical connections.
Failure to do so can result in death, fire, or
electrical shock.
Electrical
Connection
Options
1, Choose electrical
connection
type
Power supply cord 4-wire receptacle
(NEMA Type 14-30R): Go to "4-wire
Power Supply Cord Connection"
section.
Then, go to "Venting Requirements."
Power supply cord 3-wire receptacle
(NEMA Type 10-30R): Go to "3-wire
Power Supply Cord Connection"
section.
Then go to "Venting Requirements."
4-wire direct connection: Go to "4-wire
Direct Wire Connection"
section. Then go
to "Venting Requirements."
3-wire direct connection: Go to "3-wire
Direct Wire Connection"
section. Then go
to "Venting Requirements."
NOTE:
If local codes do not permit connection of a
cabinet-ground
conductor to neutral wire, go to "Optional
3-Wire Connection"
section. This connection may be
used with either a power supply cord or a direct wire
connection.
2, Remove terminal
block
cover
B
C
A
Before you start, disconnect
power. Remove hold-down
screw (D) and terminal block cover (A).
A. Terminal block cover
B. External ground conductor
screw
C. Center terminal block screw
D. Hold-down
screw
E. Neutral ground wire
E Hole below terminal block cover