Electrical Connection

WARNING
Electric Shock Hazard
This dryer must be earthed.
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or
electric shock.
This is a 3-wire dryer which must be earthed.
This dryer is supplied without an electric cord and plug; it must
be connected by a competent electrician.
In Australia, each single electric dryer is fitted with a cord and
plug. See "Electrical Requirements."

Connect Vent

1. Using a 102 mm (4") clamp, connect vent to exhaust outlet
in dryer. If connecting to existing vent, make sure the vent is
clean. The dryer vent must fit over the dryer exhaust outlet
and inside the exhaust hood. Make sure the vent is secured
to exhaust hood with a 102 mm (4") clamp.
2. Move dryer into final position. Do not crush or kink vent.
Make sure dryer is level.

Complete Installation

1. With dryer in final position, place level on top of the dryer, first
side to side; then front to back. If the dryer is not level, adjust
the legs of the dryer up or down until the dryer is level.
2. Switch on power supply.
3. Check dryer operation (some accumulated time may be on
the timer due to factory testing).
Insert coins in slide and press slide in slowly. (Operating time
will accumulate per number of coins and type of timing cam
used.) Push START/RESTART button. Using a full heat cycle
(not the air cycle), let the dryer run for at least five minutes.
Dryer will stop when time is used up.
NOTE: Dryer door must be closed for dryer to operate. When
door is open, dryer stops, but timer continues to run. To
restart dryer, close door and push START/RESTART button.
4. If drying time is too long, make sure lint screen is clean.
5. Now start the dryer and allow it to complete a full heat cycle
(not air cycle) to make sure it is working properly.
8

MAINTENANCE INSTRUCTIONS

Maintenance instructions:
Clean lint screen after each cycle.
Removing accumulated lint (disconnect dryer from electricity
supply before starting this task):
From inside the dryer cabinet:
Lint should be removed every 2 years or more often,
depending on dryer usage. Cleaning should be done by a
qualified person.
From the exhaust vent:
Lint should be removed every 2 years, or more often,
depending on dryer usage.
If dryer does not operate check the following:
Electric supply is connected.
Circuit breaker is not tripped or fuse is not blown.
Door is closed.
Controls are set in a running or "ON" position.
START button has been pushed firmly.
If you need assistance:
Contact your authorized Maytag Commercial Laundry distributor.
When you call, you will need the dryer model number and serial
number. Both numbers can be found on the serial-rating plate
located on your appliance. Or visit:
www.MaytagCommercialLaundry.com.
Manufacturer: Whirlpool Corporation, Benton Harbor, Michigan
49022, U.S.A.
Manufacturing site: Whirlpool Corporation, 1300 Marion-Agosta
Road, Marion, OH 43302, U.S.A.
EU representative: Maytag UK Ltd, Redhill, RH1 1AX, UK,
& Bauknecht Hausgerate GmbH, D-73614 Schorndorf, Germany
EU - DECLARATION OF CONFORMITY
CE - DECLARATION DE CONFORMITE
BAUKNECHT HAUSGERÄTE GmbH, D-73614 Schorndorf
WE (nous):
WHIRLPOOL EUROPE S.r.l I-21025 COMERIO
representing (représentant):
declare under our sole responsibility that the product
déclarons sous notre propre responsabilité que le produit
Maytag
dryer
(sèche-linge) :
Maytag
to which this declaration relates is in conformity with the following standard(s) or other
normative document(s)
auquel se référe cette déclaration est conforme aux normes suivantes ou autres documents normatifs
EN 60335-1:2002+A1+A2+A11+A12+A13
EN 60335-2-11:2003+A1+A2
EN 50366:2003+A1:2006
EN ISO 10472-1:2008
EN ISO 10472-4:2008
EN 55014-1:2006
EN 61000-3-2:2006
EN 61000-3-11:2000
following the provisions of Directive(s):
suivant les prévisions des Directives :
2006/95/EC LOW VOLTAGE DIRECTIVE
2004/108/EC ELECTROMAGNETIC COMPATIBILITY DIRECTIVE
Electro-magnétique)
2006/42/EC MACHINERY DIRECTIVE
Schorndorf, 29.04.2010
Place and date:
lieu et date :
MDE17CS
MDE17MN
(CEE Directive Basse Tension)
(CEE Directive Compatibilité
represented by
Roberto Mottura
Director PDC, FC

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mde17cs

Table of Contents