Power SuppMy Cord Connection
Power
supply
cord
strain
relief
_1, Attach power supply cord
strain
relief
A
B
C
D
Remove the screws from a 3/4" (19 mm) UL listed strain relief
(UL marking on strain relief). Put the tabs of the two clamp
sections (C) into the hole below the terminal block opening
(B) so that one tab is pointing up (A) and the other is pointing
down (D), and hold in place. Tighten strain relief screws just
enough to hold the two clamp sections (C) together.
Z,
Attach power supply
cord
to strain
relief
4oWire Power Supply Cord Connection
iMPORTANT:
A 4-wire connection is required for mobile
homes and where local codes do not permit the use of 3-wire
connections.
4-wire receptacle
(NEMA type 14-30R)
4-prong plug
Spade terminals with
upturned ends
I
Ring terminals
Prepare
to connect
neutral
ground
wire and neutral
wire
Put power supply cord through the strain relief. Be sure that
the wire insulation on the power supply cord is inside the
strain relief. The strain relief should have a tight fit with the
dryer cabinet and be in a horizontal position. Do not further
tighten strain relief screws at this point.
if your outlet looks like this:
(_
Power supply cord 4-wire receptacle
(NEMA Type 14-30R):
Go to "4-Wire Power Supply Cord
Connection"
on this page.
if your outlet looks like this:
__
Power supply cord 3-wire receptacle
(NEMA Type 10-30R):
Go to "3-Wire Power Supply Cord
Connection"
on page 9.
Remove center terminal block screw (B). Remove neutral
ground wire (E) from external ground conductor screw (A).
Connect
neutral
ground wire
and neutral
wire
Connect neutral ground wire (E) and neutral wire (white or
center) (C) of power supply cord under center terminal block
screw (B). Tighten screw.