Instafl Leveling Legs; Electrical Connection - Maytag MEDC215EW0 Installation Instructions Manual

29" wide models
Hide thumbs Also See for MEDC215EW0:
Table of Contents

Advertisement

Install Leveling Legs
Excessive Weight Hazard
Use two or more people to move and install dryer.
Failure to do so can result in back or other injury.
"1,
Prepare dryer for leveling legs
.............
iii
To avoid damaging floor, use a large flat piece of cardboard
from dryer carton; place under entire back edge of dryer.
Firmly grasp dryer body (not console panel) and gently lay
dryer down on cardboard.
2,
Screw
in leveling
legs
Using a wrench and tape measure, screw legs into leg holes
until bottom of foot is approximately
1/2" (13 mm) (to match
height of 3.6 cu. ft. capacity washer) or 11/2 '' (38 mm) (to
match height of 3.8 cu. ft. capacity washer) from bottom of
dryer.
Now stand the dryer on its legs. Slide the dryer until it is
close to its final location. Leave enough room for electrical
connection
and to connect the exhaust vent.
Electrical
Connection
Power Supply Cord
Fire Hazard
Use a new LIL listed 30 amp power supply cord.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal
(silver).
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining 2 supply wires to remaining
2 terminals
(gold).
Securely tighten
all electrical connections.
Failure to do so can result in death, fire, or
electrical shock.
Electrical Connection Options
1, Choose electrical
connection
type
Power supply cord 4=wire receptacle
(NEMA Type 14-30R): Go to steps 1-2 on
page 9 for power supply cord strain relief:
then steps 3-6 for 4-wire Power Supply
Cord Connection
section. Then, go to
Venting Requirements.
Power supply cord 3=wire receptacle
(NEMA Type 10=30R): Go to steps 1-2 on
page 9 for power supply cord strain relief:
then steps 3-5 for 3-wire Power Supply
Cord Connection
section.
Then go to Venting Requirements.
4-wire direct connection:
Go to steps
1-2 on page 10 for direct wire strain relief:
then steps 3-8 for 4-wire Direct Wire
Connection section. Then go to Venting
Requirements.
3-wire direct connection: Go to steps
1-2 on page 11 for direct wire strain relief:
then steps 3-7 for 3-wire Direct Wire
Connection section. Then go to Venting
Requirements.
NOTE: If local codes do not permit connection of a
cabinet-ground
conductor
to neutral wire, go to "Optional
3-wire Connection"
section. This connection may be
used with either a power supply cord or a direct wire
connection.