Maytag MEDX5SPAW0 Installation Instructions Manual page 11

27" wide models
Hide thumbs Also See for MEDX5SPAW0:
Table of Contents

Advertisement

Available languages

Available languages

3.
connect
neutral
ground wire
and neutral
wire
C
E
Connect neutral ground wire (E) and place
hooked end (hook facing right) of neutral
wire (white or center wire) (C) of direct
wire cable under center screw of terminal
block (B). Squeeze hooked ends together
and tighten screw.
4. Connect
ground
wire
Connect ground wire (green or bare) (F) of direct wire cable
to external ground conductor screw (A). Tighten screw.
3oWire Direct Wire Connection
iMPORTANT:
Use where local codes permit connecting
cabinet-ground
conductor to neutral wire.
f-I", Prepare your 3-wire cable for
direct
connection
Direct wire cable must have 5 ft. (1.52 m) of extra length so
dryer may be moved if needed.
Strip 31/2'' (89 mm) of outer covering from end of cable. Strip
insulation back 1" (25 mm). If using 3-wire cable with ground
wire, cut bare wire even with outer covering. Shape wire ends
into hooks.
Remove center terminal block screw (B).
Place hooked ends of remaining direct wire cable wires
under outer terminal block screws (hooks facing right).
Squeeze hooked ends together and tighten screws. Finally,
reinsert tab of terminal block cover into slot of dryer rear
panel. Secure cover with hold-down screw. Now, go to
"Venting Requirements."