MEDX700X
Electrical
:
This dryer requires a 3 or 4 wire, single
phase, 120/240 volt, 60 Hz., AC only electrical supply
(or 3 or 4 wire, 120/208 volt electrical supply, if speci-
fied on the serial/rating plate) on a separate 30-amp
circuit, fused on both sides of the line. A time-delay
fuse or circuit breaker is recommended. Connect to
an individual branch circuit. Do not have a fuse in the
neutral or grounding circuit.
:
Exhaust venting
Exhaust your dryer to the outside.
4" (102 mm) diameter vent is required. Rigid or flexible
metal exhaust vent must be used. Do not use plastic
or metal foil vet. Exhaust hood must be at least
12" (305 mm) from the ground or any object that
may be in the path of the exhaust.
Hood styles: A & B are recommended.
A
A. Louvered hood
B. Box hood
C. Angled hood (acceptable)
C
The vent system chart provides venting requirments
that will help to achieve the best drying performance.
Vent system chart:
NOTE: Side and bottom exhaust installations have
a 90° turn inside the dryer. To determine maximum
exhaust length, add one 90° turn to the chart.
Vent System Chart
Type
Box/louvered
Number of
of vent
90° turns
or elbows
0
Rigid metal
64 ft. (20 m)
1
Rigid metal
54 ft. (16.5 m)
2
Rigid metal
44 ft. (13.4 m)
3
Rigid metal
35 ft. (10.7 m)
Select the route that will provide the straightest and
most direct path outdoors. Plan the installation to
use the fewest number of elbows and turns. Use the
4
27 ft. (8.2 m)
Rigid metal
fewest 90° turns possible.
Do not use vent runs longer than specified in vent
length chart. Determine the number of elbows you
will need.
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
27" Wide Electric Dryer
B
Angled
hoods
hoods
58 ft. (17.7 m)
48 ft. (14.6 m)
38 ft. (11.6 m)
29 ft. (8.8 m)
21 ft. (6.4 m)
OVERALL DIMENSIONS

Dryer dimensions

43"
(1092 mm)
*29
/
"
1
2
(749 mm)
27"
(687 mm)
A
A. Large opening side-swing door
B. Wide opening hamper door
The location must be large enough to allow the dryer door to open fully.
Minimum required spacing for recessed or closet installation
18"*
(457 mm)
27"
1"
1"
1"*
(25 mm)
(686 mm)
(25 mm)
(25 mm)
A
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
*Additional spacing recommended
The dimensions shown following are for the minimum spacing allowed.
Additional spacing should be considered for ease of installation and servicing.
Additional clearances might be required for wall, door, and floor moldings.
Additional spacing of 1" (25 mm) on all sides of the dryer is recommended to
reduce noise transfer.
For closet installation, with a door, minimum ventilation openings in the top and
bottom of the door are required.
Louvered doors with equivalent ventilation openings
are acceptable.
Companion appliance spacing should also be considered.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
23¾"
(603 mm)
43"
(1092 mm)
*29
/
"
1
2
(749 mm)
27"
(687 mm)
B
14" max.*
2
48 in.
*
(356 mm)
2
(310 cm )
*
2
24 in.
2
(155 cm )
29
5
¼"
½"*
(743 mm)
(140 mm)
B
C
13¾"
(349 mm)
3"*
(76 mm)
3"*
(76 mm)
Ref. W10115226B
01/2011