Power S upply Cord
Electrical Shock Hazard
Disconnect power before servicing.
Use a new 40 amp power supply cord.
Plug into a grounded outlet.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Direct Wire
Electrical
Shock Hazard
Disconnect
power before servicing.
Use 8 gauge copper
or 6 gauge aluminum
wire.
Electrically
ground
range.
Failure to follow these instructions can result in death,
fire, or electrical
shock.
1.
2.
Disconnect
power.
Remove the terminal block cover screws located on the back
of the range. Pull cover down and toward you to remove
cover.
4.
Add strain relief.
Style 1: Power supply cord strain relief
Remove the knockout for the 40-amp supply cord.
Assemble a UL listed strain relief in the opening.
A. Hold-down
screws
B. Terminal block cover
A. UL listed strain relief
3. Remove plastic tag holding three 10-32 hex nuts from the
middle post of the terminal block.
Feed the power supply cord behind the black horizontal
cross brace and through the strain relief, allowing enough
slack to easily attach the wiring to the terminal block.
A
A. Black horizontal cross brace
B. Power supply cord