RS-232C/RS-422A Protocol
RS-232C/RS-422A Protocol
C-14
A protocol is a set of rules the computer follows in sending data to the printer. The RS-232C/RS-422A
parameters are stored in battery backed-up memory. They are indicated on the status printout. They
can be changed by the FRPO (firmware reprogram) command described in the Programming Manual .
The parameters and their identification codes are given below.
H1: Baud rate
Parameter value
3
6
12
24
48
96
19
38
57
11
The factory setting is 9600 baud.
H2: Data bits
7 or 8, factory-set to 8.
H3: Stop bits
1 or 2, factory-set to 1.
Baud rate
300
600
1200
2400
4800
9600
19200
38400
57600
115200