Download Print this page

Whirlpool SF216LXSQ2 Installation Instructions Manual page 9

30" (76.2 cm) freestanding gas range
Hide thumbs Also See for SF216LXSQ2:

Advertisement

Available languages

Available languages

2=
3=
Check that the gas pressure regulator shutoff valve is in the
"on" position.
f
LJ
Front View
Front
Side View
Shutoff valve
"ON" Position ....
Open the manual shutoff valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
When the oven control is turned to the desired setting, a hot
surface igniter heats to a bright orange and ignites the gas. No
sparking occurs. The glow bar remains on while the burner
operates.
Check Operation of Cooktop Burners
1=
2.
If control panel and knobs were removed earlier, reinstall
knobs.
Push in and turn each surface unit control knob to "LITE"
position. The flame should light within 4 seconds.
eo
OF
O0
LIT/
LO
4=
5=
6.
A. Closed valve
B. Open valve
Test all connections by brushing on an approved noncorrosive
leak-detection
solution. Bubbles will show a leak. Correct any
leak found.
Close the broiler door.
Remove cooktop burner caps and grates from parts package.
Align notches in burner caps with pins in burner base. Burner
caps should be level when properly positioned. If burner caps
are not properly positioned, surface burners will not light.
Place burners, burner caps and grates on the cooktop.
3=
4.
MED
Turn control knob to "HI" position after burner lights.
Check each cooktop burner for proper flame. The small inner
flame should have a very distinct blue flame 1¼,, ( 0.64 cm) to
1/2"(0.13 cm) long. The outer cone is not as distinct as the
inner cone.
Electrical Shock Hazard
Plug into a grounded
3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension
cord.
Failure to follow these instructions can result in death,
fire, or electrical
shock.
A. Outer cone
B. Inner cone
5. Turn the control knob quickly to the "LO" position after the
burner lights. If the flame goes out, turn the control knob to
the "OFF" position.
6. Check each cooktop burner for proper low flame. The low
flame should be a minimum, steady blue flame. The flame size
should be W' to 3/8"(0.64 cm to 0.95 cm) high.
If the low flame
needs adjusting:
1. Turn control knob to the "Lo" setting and remove control
knob.
2=
Insert a small flat-blade screwdriver into the valve stem. Turn
the valve adjusting screw to obtain the smallest flame that will
not go out when the control of a cold burner is quickly turned
from "HI" to "Lo." Turn right to decrease flame height. Turn left
to increase flame height. Repeat for other cooktop burners as
needed.
7. Plug into a grounded 3 prong outlet.
Electronic
Ignition System
Initial lighting and gas flame adjustments
Cooktop and oven burners use electronic igniters in place of
standing pilots. When the cooktop control knob is turned to the
"LITE" position, the system creates a spark to light the burner.
This sparking continues until the control knob is turned to the
desired setting.
A. Valvestem
3. Replace control knob.

Advertisement

loading

This manual is also suitable for:

Sf216lxsm2