1. Check t hat t heanti-tip b racket isinstalled:
• Look fortheanti-tip bracket securely attached tothefloor.
• Slide therange back sotherear r ange f ootisunder theanti-
tipbracket.
1=
2.
Place rack in oven.
Place level on rack and check levelness of range, first side to
side; then front to back.
3.
If range is not level, pull range forward until rear leveling leg is
removed from the anti-tip bracket. Use 3/8"drive ratchet and
wrench or pliers to adjust leveling legs up or down until range
is level.
4. Push range back into position.
5. Check that rear leveling leg is engaged in anti-tip bracket.
NOTE: Range must be level for satisfactory
baking performance.
Explosion Hazard
Use a new CSA (nternational
approved
gas supply
line.
install a shut=off valve.
Securely tighten
all gas connections.
if connected to LP, have a qualified
person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified
person include:
licensed heating personnel,
authorized
gas company
personnel, and
authorized
service
personnel.
Failure to do so can result in death, explosion,
or fire.
Typical rigid pipe connection
A combination
of pipe fittings must be used to connect the range
to the existing gas line. Your connections may be different,
according to the supply line type, size and location.
1. Apply pipe-joint compound
made for use with LP gas to all
pipe thread connections.
2. Using a pipe wrench to tighten, connect the gas supply to the
range.
B
C
G
........................................
A. Pressure regulator
connection
fitting
B. 90 ° elbow
C. Black iron pipe
D. Union
E. Nipple
F Manual shutoff valve
G. V2"or 3/4"gas pipe
Typical flexible
connection
1. Apply pipe-joint compound
made for use with LP gas to the
smaller thread ends of the flexible connector adapters (see B
and F in the following illustration).
2. Attach one adapter to the gas pressure regulator and the other
adapter to the gas shutoff valve. Tighten both adapters.
3. Use a combination
wrench and pliers to attach the flexible
connector to the adapters. Check that connector is not
kinked.
A
......................
D
............ _
F
E
G
H ................................
A. Pressure regulator
E.Adapter
connection fitting
F Usepipe-joint compound.
B. Use pipe-joint compound.
G.Manual shutoff valve
C. Adapter
H. Y2"or 3/4" gas pipe
D. Flexible connector
Complete Connection
1. Locate gas pressure regulator in the broiler.
A. Gas pressure regulator
IMPORTANT: Do not remove the gas pressure regulator.