Summary of Contents for PSC HS1250,

  • Page 1 HS1250 UIDE...
  • Page 2 This manual and the procedures described in it are copyrighted, with all rights reserved. Under copyright law, this manual may not be copied in whole or part without prior written consent from PSC. The same proprietary and copyright notice must appear on any permitted copies as appears on the original. This exception does not permit copies to be made for others, whether or not sold.
  • Page 3: Table Of Contents

    ABLE OF ONTENTS ------------------------------------------------- 3 RODUCT VERVIEW -------------------------------------------------- 4 ANUAL VERVIEW --------------------------------------------- 4 PERATIONAL VERVIEW ---------------------------------------------- 5 ONTROLS NDICATORS ------------------------------------------------ 5 OLUME WITCH ------------------------------------------------ 6 NDICATOR -------------------------------------------------------- 7 PEAKER -------------------------------------------------------- 8 ONNECTORS ---------------------------------------------------- 9 OTION ENSOR --------------------------------------------------------- 10 NPACKING ---------------------------------------- 11 ERIFY CANNER PERATION...
  • Page 4 HS1250 HS1250 User's Guide...
  • Page 5: Product Overview

    The HS1250 also provides a connection for an optional undecoded handheld scanner, such as the PSC model SP400 , allowing heavy or large items to be scanned without removal from the shopping cart.
  • Page 6: Anual Verview

    Programming Mode, you cannot scan normal barcodes and the scanner will not send data to the host. A Programming Kit for the HS1250 is available from PSC or your dealer or distributor. Ask for part number R44-1340.
  • Page 7: Controls

    & I ONTROLS NDICATORS The descriptions on the following pages detail the function of the controls and indicators for the HS1250. Note that two of these items, the speaker and volume switch, are located beneath the scanner's top cover. OLUME WITCH While the scanner is in Normal Mode and the green lamp is on dim, you can easily change the volume on the HS1250 scanner by pressing...
  • Page 8: Indicator Lamp

    NDICATORS NDICATOR LAMP The indicator lamp has six active modes; off, on dim, flash once, flashing continually once per second, flashing continually twice per second and repeating a series of flashes. Off indicates that either there is no power to the scanner or the scanner is not operational.
  • Page 9: Speaker

    PEAKER The speaker produces an audible indication of scanner operation. It sounds a normal tone, an alternate tone, or an error tone (a repeating series of tones). ORMAL The normal tone sounds when a barcode label is recognized, its content is decoded and the data is transmitted to the host. LTERNATE The alternate tone has a lower pitch than the normal tone.
  • Page 10: Connectors

    ONNECTORS Three cable connections are located on the scanner as shown below, with the DC power and Handheld connections in a niche near the serial number label and the Interface connection in a recessed area of an adjacent side of the scanner.
  • Page 11: Motion Sensor

    The DC power connector is for attaching the AC/DC power supply to the scanner. This connector supplies +12VDC, -12VDC and +5VDC to the scanner. NOTE Use ONLY approved AC/DC power supplies ordered from PSC. DDITIONAL EATURE OTION SENSOR The scanner includes a motion sensor that detects activity in front of the scan window.
  • Page 12: Unpacking

    If anything is missing or the wrong power cord or interface cable has been included with your scanner, contact your dealer, distributor or call your local PSC office. In the U.S. and Canada call PSC Customer Support Services at (800) 547-2507. Otherwise, refer to the list on the back cover for the subsidiary most convenient to you.
  • Page 13: Canner Operation

    ERIFYING CANNER PERATION Prior to installation, we recommend that you connect the scanner and power supply to AC power to ensure that the scanner is fully functional. 1. Plug the DC power connector from the AC/DC power supply into the scanner. 2.
  • Page 14: Installation

    NSTALLATION OUNTER ODIFICATION The HS1250 scanner is designed to optimize usable counter space by mounting horizontally flush with the counter. The following instructions provide optional mounting plans, allowing flexibility in method, while ensuring a stable and secure installation. 1. Choose the installation location. Product flow, cable routing and ease of use should all be considered.
  • Page 15 3. For Option a, cut a hole in the countertop using the dimensions below, with a corner radius of " (6.35mm). The shelf supporting the scanner should be 3.45" (closest fractional = 3 ") (8.76cm) below the top of the counter. PTION A Radius "...
  • Page 16 4. For Option b, reference the counter cutout dimen- sions below. Radius corners at " (6.35mm). To adequately support the scanner, counter thickness must be at least " (19mm). PTION B Radius " (6.35mm) 4x Routed Edge 8 " (22.22cm) 7 "...
  • Page 17: Hookup

    OOKUP 1. Route all cables up through the opening. 2. Connect the interface cable to the scanner and secure it with the mounting screw, ensuring that the cable is routed inside the cable clip. 3. Attach the DC power connector from the AC/DC power supply to the scanner's power connector.
  • Page 18: Power -U P Procedure

    Problem Isolation on the next page. If you want to modify the scanner's interface parameters or change the user interface (e.g. volume), order the HS1250/VS1200 Programming Kit (PSC Part Number R44-1340). HS1250 User's Guide...
  • Page 19: Connecting The Scanner

    ONNECTING CANNER Switch the terminal power off. 2. Connect the interface cable to the terminal. To Scanner Connect the IEC power cord to the AC outlet 4. Switch on the terminal power. Verify the system's operation by scanning a few product labels. 5.
  • Page 20: Troubleshooting

    ROUBLESHOOTING ROBLEM SOLATION START Verify that the - the green 1. AC/DC power supply is con- lamp nected to a functional AC outlet. lit (dim)* 2. Power cord is firmly connected to the AC/DC Power Supply. 3. AC/DC Power Supply is firmly * If the green lamp is flashing connected to scanner.
  • Page 21: Isolated Scanner Test

    ROUBLESHOOTING SOLATED CANNER 1. DISCONNECT POWER Disconnect the AC/DC Power Supply from the AC power outlet. scanner pass self-test • Record the number of tones emitted by the 2. DISCONNECT INTERFACE scanner. Disconnect the interface cable • Call your system support between the scanner &...
  • Page 22: Operation

    HS1250 OW TO CAN WITH THE The HS1250 is mounted flush with the countertop to allow maximum work area and enable slide-through scanning. A dense scan pattern ensures that a barcode is easily read when swept over the scan window in the direction of the arrow. The scanner’s Read Zone, extends approximately 6"...
  • Page 23: Customizing Your Scanner ' S Operation

    The list on page 24 shows the additional features that may be changed using the labels contained in the Programming Kit (PSC part number R44-1340). HANGING There are three possible tone selections. Each time you scan this label, the scanner's tone will change to the next highest tone.
  • Page 24: Changing The Volume

    HANGING OLUME There are three possible volume settings. Each time you scan this label, the scanner's volume will change to the next highest level. If the current volume is the highest selection, the selection will return to the lowest setting. Increment Volume HS1250 User's Guide...
  • Page 25: Other Programmable Features

    ROGRAMMING Programming describes the process of changing scanner features using the special barcode labels contained in the Programming Kit (R44-1340). When the scanner is placed in Programming Mode, the scanner will not read any standard barcode labels or transmit any data to the host.
  • Page 26: Routine Maintenance

    OUTINE AINTENANCE HS1250 maintenance procedures consist of window cleaning and window replacement. LEANING The scanner actually has two windows; upper and lower. While the top of the upper scan window may require periodic cleaning due to spillage, surface dust, etc., other window surfaces are unlikely to need much atten- tion.
  • Page 27 R44-1430...
  • Page 28: Window Replacement

    INDOW EPLACEMENT If the scanner's upper window becomes scratched, it can be easily replaced by following the procedures on this page. 1. Insert a coin into the slot on the scanner’s edge and use it to gently pry the top cover from the scanner. 2.
  • Page 29: Efinitions

    PPENDIX YMBOLS EFINITIONS We have selected the symbols on the following pages to help ensure clear communication with non-English speaking users. --------------------- A.C. D.C C ONVERTER --------------------- A.C. C URRENT --------------------- B RIGHTNESS UNLIGHT --------------------- C LEANING --------------------- C OMMUNICATION IDIRECTIONAL R44-1430...
  • Page 30 --------------------- D.C. C URRENT --------------------- H UMIDITY --------------------- L ISUAL NDICATOR --------------------- M OTION ENSOR --------------------- O PERATOR --------------------- S PEAKER HS1250 User's Guide...
  • Page 31 --------------------- S WITCH OLUME --------------------- T --------------------- T EMPERATURE AXIMUM --------------------- T EMPERATURE INIMUM --------------------- V OLTAGE ANGEROUS R44-1430...
  • Page 32: Pecifications

    PPENDIX PECIFICATIONS HYSICAL PECIFICATIONS CANNER Depth = 3.45" (8.76cm) Length = 7.6" (19.3cm) Width = 9.0" (22.9cm) Weight = 4 lb 11oz (2.13 kg) AC/DC P OWER UPPLY Length = 5.0" (12.7 cm) Width = 3.0" (7.6 cm) Height = 1.5" (3.8 cm) Weight = 1.0 lb (.6 kg) HS1250 User's Guide...
  • Page 33 NVIRONMENTAL PECIFICATIONS PERATION EMPERATURE 10 C (50 F) 40 C (104 F) UMIDITY 5 - 90 % (non-condensing) MBIENT IGHT 200 footcandles (2150 Lux) maximum TORAGE EMPERATURE -40 C (-40 F) 70 C (158 F) UMIDITY 5 - 95 % (non-condensing) R44-1430...
  • Page 34 LECTRICAL PECIFICATIONS USE ONLY POWER SUPPLY (P/N 8-0133) OR OTHER PSC AP- PROVED POWER SUPPLY. The AC/DC Power Supply provides three dc voltages to the HS1250 ; +12 volts, -12 volts and +5 volts. Typical current draw is: +12vdc ........315mA (normal operation) ..........665mA (during start-up)
  • Page 35: Egulatory

    PPENDIX EGULATORY GENCY NFORMATION FCC S TATEMENTS This device complies with Part 15 of the FCC rules and the Radio Interference Regulation of the Canadian Department of Communica- tions for a Class A computing device. Operation is subject to the following two conditions: 1.
  • Page 36 This is to certify that the HS1250 scanner is shielded against radio interference in accordance with the provisions of VDE 0871 B. This product complies with the EMC Directive which allows PSC to affix the CE mark to the product. Compliment consist of meeting the EMC Directive (89/336/EEC + 92/31/EEC + 96/68/EEC) for electromag- netic compatibility within the European communities.
  • Page 37 -12VDC @ 0.20A MODEL: HS1250 Sicherheit POWER: COVERED BY ONE OR MORE OF THE FOLLOWING PATENTS 17 Watts (max) MFTD: Feb 1995 I/F: RS-232 Other Patents Pending BRICK: 8-0133 VCCI – I Brick:Use ONLY PSC AC/DC Power Supply P/N 8-0133. R44-1430...
  • Page 38 ASER AFETY NFORMATION The HS1250 scanner requirements for laser safety are based on IEC Standard Publication 825 and CDRH 21CFR, Chapter 1, Subchapter J and (CDRH) Laser Product Performance Standard published November 28, 1978, User information [1040.10(h)1]: 1. User Maintenance. No user maintenance of the system other than window replacement and cleaning is required.
  • Page 39 ADVARSEL Forsøg ikke at åbne eller reparere komponenter i det optiske hulrum. Uautoriseret åbning eller reparation af komponenter i det optiske hulrum kan være en overtrædelse at lasersillerhedsregulativer. Det optiske system me udelukkende repareres af PSC autoriserede reparationscentre. R44-1430...
  • Page 40 INNISH HS1250 on hyväksytty Yhdysvalloissa vastaamaan DHHS/CDRH 21CFR Subchapter J luokka IIa (Class IIa) lasertuotteille asetettuja vaatimuksia. HS1250 on myös hyväksytty vastaamaan IEC 825-1:1993 vaatimuksia I luokan (Class I) lasertuotteille. Luokka I (Class I) ja luokka IIa (Class IIa) tuotteiden ei katsota olevan vaarallisia. HS1250 on sisäinen Visible Laser Diode (VLD) joka säteilee enintään 0,652 milliwattia 670 nanometrin aallonpituudella.
  • Page 41 ERMAN Der HS1250 entspricht den in den Vereinigten Staaten geltenden Vorschriften des DHHS/CDRH 21CFR Subchapter J für Laserprodukte der Klasse IIa (Class IIa). Der HS1250 ist ferner als ein Laserprodukt der Klasse I (Class I) nach den Vorschriften der IEC 825-1:1993 zugelassen. Produkte der Klasse I (Class I) und der Klasse IIa (Class IIa) sind als ungefährlich eingestuft.
  • Page 42 TALIAN HS1250 è stato certificato negli Stati Uniti in conformità alle norme DHHS/CDRH 21 CFR Subchapter J per i prodotti laser della categoria IIa. HS1250 è anche certificato come prodotto laser di categoria I, secondo le norme IEC 825-1:1993. I prodotti delle categorie I e IIa non sono considerati pericolosi. HS1250 contiene all’interno un diodo a laser visibile (VLD), che emette un massimo di 0,652 milliwatt ad una lunghezza d’onda di 670 nanometri.
  • Page 43 ORTUGUESE O HS1250 é certificado nos Estados Unidos em conformidade com os requerimentos do DHHS/ CDRH 21 CFR Subcapítulo J para produtos a laser de Classe IIa (Class IIa). O HS1250 também é certificado como um produto a laser de Classe I (Class I) de acordo com os requerimentos do IEC 825-1:1993.
  • Page 44 PANISH El HS1250 ha sido certificado en los EE.UU. conforme a los requisitos de DHHS/CDRH 21CFR Subchapter J para productos láser Clase IIa (Class IIa). El HS1250 también ha sido certificado como un producto láser Clase I (Class I) según los requisitos de IEC 825-1:1993. Los productos Clase I (Class I) y CLase IIa (Class IIa) no se consideran peligrosos.
  • Page 45 EBREW HS1250 HS1250 IEC 825-1:1993 HS1250 0.652 R44-1430...
  • Page 46 HS1250 User's Guide...
  • Page 47 PSC shall pay for the return of the product to Customer if the shipment is to a location within the country in which the PSC service center is located. Customer shall be responsible for paying all shipping charges, duties, taxes, and any other charges for products returned to any other locations.
  • Page 48 Hong Kong Telephone: [39] (0) 39/62903.1 Telephone: [852]-2-584-6210 Telefax: [852]-2-521-0291 Telefax: [39] (0) 39/685496 Australia Japan PSC Asia Pacific Pty Ltd. PSC Japan K.K. North Ryde, Australia Shinagawa-ku, Tokyo, Japan Telephone: [61]0(2)9878 8999 Telephone: 81 (0)3 3491 6761 Telefax: [61]0(2)9878 8688...