The speaker produces an audible indication of scanner operation. It
sounds a normal tone, an alternate tone, or an error tone (a repeating
series of tones).
N
T
ORMAL
ONE
The normal tone sounds when a barcode label is recognized, its
content is decoded and the data is transmitted to the host.
A
T
LTERNATE
ONE
The alternate tone has a lower pitch than the normal tone. It is
sounded in four different situations:
In Normal Mode when the barcode has been read but the
scanner is not programmed to transmit that symbology to
the host.
In Normal Mode when the HS1250 cannot successfully decode
a barcode label.
When in Programming Mode, any programming label that
your scanner cannot use (e.g. Baud Rate for any interface
other than RS-232) is rejected and the alternate tone is
sounded.
E
T
RROR
ONE
The error tone alerts the operator of possible system or component
failure and only sounds when a problem is detected.
Number of Tones
1
2
3
4
7
R44-1430
S
PEAKER
Failed Components
Digital Board
VLD (Visible Laser Diode) Module
Motor
Digital Board
VLD (End of life)
7