All gas connections
must be made according
to national
and local codes.
This
gas supply (service) line must be the same size or greater than the inlet line of the
appliance.
Sealant on all pipe joints must be resistant to te action of LP/Propane
gas.
The range is equipped
for the use with NATURAL gas. It is design-certified
by CSA
International
for NATURAL and L.R gases with appropriate
conversion.
The model/serial
rating plate, located on the back of the appliance,
has information
on the type of gas that can be used. If this information
does not agree with the type
of gas available, check with the local gas supplier. See page from 17 to 20 for L.R
gas conversion
inctructions.
1. Manual
Shut-off
Valve (fig.2.1):
The supply line shall be equipped with an approved shutoff valve. This valve should
be located in the same room as the range and should be in a location that allows
ease of opening
and closing (in a position
where it can be reached quickly
in the
event of an emergency).
Do not block access to the shutoff valve. The valve is for turning
on or shutting off
gas to the appliance.
Shutoff valve
"open" position
To range
\
_e
Fig. 2.1
WARNING
Explosion
Hazard
Use a new CSA or UL approved
gas supply line.
Install a shut-off
valve.
Securely tighten all gas connec-
tions.
If connected to LP, have a quali-
fied person make sure gas pres-
sure does not exceed 14" water
column.
Examples of a qualified person
include
licensed
heating
per-
sonnel, authorized
gas compa-
ny personnel,
and
authorized
service personnel.
Failure to do so can result in
death, explosion, or fire.
2. Pressure
Regulator:
a) All heavy duty, commercial type cooking equipment
must have a pressure regulator
on the incoming service line for safe and efficient operation,
since service pressure
may fluctuate
with local demand.
Before installing the regulator mount the 1/2" NPT (conical) male connector to the
regulator (see picture 2.2a). Gasket supplied have to be placed between
1/2" NPT
(conical) connector/extension
pipe male pipe fitting (see picture 2.2b).
The regulator supplied with this range must be installed before any gas connections
are made.
Use supplied pressure regulator only.