electrical
connection
If codes permit and a separate ground wire is used, it is recommended
that a qualified
electrician installer determine that the ground path and wire gauge are in accordance
with local codes.
Be sure that the electrical connection and wire size are adequate and in conformance
with:
- ANSl/NFPA 70 latest edition and local codes and ordinances
- CSA Standard C22.1, Canadian Electrical Code, Part 1 - latest edition, and all local
codes and ordinances.
• Do not ground to a gas pipe.
• Check with a qualified electrical
installer if you are not sure the range is properly
grounded.
• Do not have a fuse in the neutral or ground circuit.
• When a 4-wire, single phase 120/240-volt,
60Hz, AC-only electrical supply is avail-
able, a 40 amp maximum circuit protection
is required, fused on both sides of the
line.
• A time-delay fuse or circuit breaker is recommended.
• This range is equipped
with a Certified Power Cord intended to be plugged
into
a standard
14-50R wall receptacle.
Be sure the wall receptacle
is within reach of
range's final location.
• Do not use an extension cord.
In the case of substitution
of the power cord always replace it with a suitable UL or CSA
approved one (with the same technical features of the replaced cord).
Tighten the power cord by using only the power cord strain relief bracket supplied with
the appliance.
Allow enough slack to easily attach the cord terminals to the terminal
block.
These operations
must be carried out only by an authorized technician.
Electrical
Shock
Hazard
Electrically
ground
range.
Failure
to follow
these
instruc-
tions can result
in death,
fire or
electrical
shock.
standard NEMA 14-50R wall receptacle
Power supply cord with
NEMA 14-50P plug
21