VCS VIP 10 User Manual page 74

Table of Contents

Advertisement

Configuring the Receiver
It is also possible to specify whether the output should react with an bistable
(permanent) or a monostable (time limited) signal. With a permanent signal
(bistable), the activated state of the relay is maintained. With a time limited signal
(monostable), the delay can be selected after which the relay reverts to its idle
state.
You can choose various events that activate the output automatically. In this way,
for example, it is possible to switch on an audible alarm when an alarm signal is
received via the connection and switch the audible alarm off again when the
alarm signal is no longer present.
Idle state:
Select Open if the relay is to operate as a normally open contact or Closed if it
is to operate as a normally closed contact.
Operating mode:
Select an operating mode for the relay.
If, for example, a lamp switched on by an alarm is to remain lit when the alarm
has ended, select Bistable. If an acoustic signal activated by an alarm is to sound
for a period of ten seconds for example, select 10s.
Relay follows:
Select a particular event to trigger the relay. The following events can activate the
relay:
Off No relay triggering by events
Connection
Triggering whenever a connection is established
Local input 1
Triggering by the alarm input 1
Remote input 1
Triggering by a relay contact at a remote location (only when a connection is
established)
Unified picture
Triggering caused by a lack of contrast in the picture
74
Chapter 7
VIP 10 / VIP 1000