Relay Action / Relay Operation - VCS VIP 10 User Manual

Table of Contents

Advertisement

Chapter 6
Tracker
The Tracker field shows an arrow indicating the current motion vector in the
video image. The checkboxes at the corners of the field are used to select the
directions to monitor. For example, if all movements toward the left and up are to
trigger an alarm, mark the top left corner. If all movement to the left is to trigger
an alarm, mark the upper left and the lower left checkboxes.
– Observe the movement in the video image indicated by the arrow over a longer
period of time at all the relevant light levels.
– Mark the checkboxes to activate the corresponding directional components for
monitoring.

Relay action / Relay operation

You can configure the switching behavior of the relay output. Relay action can be
specified either as open switch (normally closed contact) or closed switch
(normally open contact).
It is also possible to specify whether the output signal should be bistable or
monostable. With bistable operation, the relay remains in the activated state.
With monostable operation, the delay time can be selected after which the relay
reverts to its idle state.
You can choose various events that activate the output automatically. Thus, for
example, it is possible to switch on a spotlight in response to a motion alarm and
switch it off again when the alarm situation is no longer active.
VIP 10 / VIP 1000
Configuring the Transmitter
53