Duct Mounting
h:
¸:
:
:
:
::
:
:
!
:
:
::
Bef0re beginning Duct M0untingi
! have €0_firm÷d !0cal codeS ior proper draining practiCes for hot water
i have chosen an instal!ation 10cati0n that m÷ets the ieqUirementS 0n pag÷ 4
Follow these steps to mount TrueSTEAM directly to the supply duct of the homeowner's HVAC equipment.
STEP ONE: Select a Mounting
Location
Choose a location that has access to a cold
water supply pipe.
Select a vertical or horizontal surface on the HVAC
supply duct, with adequate clearances, where
TrueSTEAM can be mounted.
M29598
Make sure there is a 120 VAC electrical outlet
rated for the TrueSTEAM model being installed.
TrueSTEAM
Required
Minimum
Modeh
Circuit
Capacity:
HM506
7 Amps
HM509
10 Amps
HM512
12 Amps
Ensure the location is near a drain with a high-
temperature water rating. Consult local plumbing
codes for proper drainage. If no main floor drain
is available, see "Appendix E: Advanced
Draining"
on page 41.
STEP TWO: Connect
the Duct Nozzle
Slide the foam gasket over the nozzle.
Make sure the o-ring gasket is properly seated
in the groove.
Insert the duct nozzle into TrueSTEAM. Twist
clockwise to ensure a tight seal.
TrueSTEAM Humidification
System
69-2285EF--01