Setting Up The Ro Filter - Honeywell TrueSTEAM HM506 Installation Manual

Hide thumbs Also See for TrueSTEAM HM506:
Table of Contents

Advertisement

Available languages

Available languages

Setting up the RO Filter
See the instruction sheet packaged with the RO Filtration System for complete installation instructions.
.
Mount the base chassis to a surface capable
of holding up to 7 pounds between the home's
cold water line and the TrueSTEAM location.
(Mounting hardware is provided.)
White Tubin(
Yellow
Tubing
Tubing
Backflow
Preventer
.
Connect the 1/4-inch white water line to the
home's main cold water supply. Connect the
other end to the inlet port on the base chassis.
.
Connect the 1/4-inch white water line to the
outlet on the base chassis. Connect the other
end to the shutoff valve. Connect the other end
to the TrueSTEAM supply fitting.
.
Connect the yellow water line to the outlet port
on the clean water storage tank. Connect the
other end to the yellow inlet port on the RO
Filter System.
5. Connect the red tubing to the reject water port
on the base chassis, and to a suitable drain on
the other end.
IMPORTANT: Refer to and follow local codes
for proper drain installation. Refer to additional
drain requirements in the TrueSTEAM
installation guide when coupling the RO Filter
drain with the TrueSTEAM drain,
TrueSTEAM Humidification
System
69-2285EF--01
43