STEP THREE:
Make Add-On Air Proving
Decision
In addition to monitoring system power and fan regulation, TrueSTEAM can monitor physical air movement
through an optional add-on air proving device. If an air proving device is added, TrueSTEAM can create steam
only if the fan is moving air through the supply duct.
[
Note: This image is not a complete
wiring diagram.
It onJy depicts add-on air proving.
See 'Wirir_g the TrueSTEAM" on page 19.
TrueSTEAM
HVAC System
R
R
C
C
WIRING BASICS
Wire TrueSTEAM R and C to HVAC system
R and C with an air proving device in-line
on C.
Configure air proving through DiP 5 on
TrueSTEAM. Set DiP 5 up and keep
DiP 4 down.
TrueSTEAM will look for physical air
movement through its C connection
before
steam enters the duct.
18
TrueSTEAM Humidification
System