Honeywell TrueSTEAM HM506 Installation Manual page 41

Hide thumbs Also See for TrueSTEAM HM506:
Table of Contents

Advertisement

Available languages

Available languages

TrueSTEAlVl Wired
to a Thermostat
in a Zoned
Application
A
Optional
Air
Proving Switch
C
HUM
HUM
VisionPro IAQ
z:L If air proving switch is used, set
TrueSTEAM DIP 4 down and DIP 5 up.
z£ Connect the thermostats,
dampers,
transformers, and sensor wires as shown
in the Truezone HZ432 panel instructions.
A In VisionPRO IAQ installer setup, set ISU
#0374 to 3.
Panel
/_
M29639
TrueSTEAlVl
RedLINK
Connection
in a Zoned
Application
C
A
Optional
Air
Proving Switch
R
W
Y
Panel
THM4000R
Wireless
Adapter
A (TrueSTEAM to Prestige)
A
A
"
A
Zones
2-4
THM4000R
Wireless
Adapter
(Zones to FocusPRO and/or Prestige)
M29640
z:L If air proving switch is used, set
TrueSTEAM DIP 4 down and DIP 5 up.
Connect the thermostats,
dampers,
transformers, and sensor wires as shown
in the Truezone HZ432 panel instructions.
A In Prestige installer setup, program
humidity calls to "Humidify Independent
of Fan."
z_ One Truezone HZ432 panel with
a RedLINK adapter will wirelessly
communicate
with 3 additional zones with
RedLINK thermostats.
TrueSTEAM Humidification
System
69-2285EF--01
39