A: Specifications
Humidifying
Capacity
HM506: up to 6 gallons per day (gpd)
(23 liters per day [Ipd])
HM509: up to 9 gpd (34 Ipd)
HM512: up to 12 gpd (45 Ipd)
Humidified Area
HM506:4,000-14,400
cubic feet
HM509:8,000-18,400
cubic feet
HM512:12,000-24,000
cubic feet
Note: Higher volumes
require more TrueSTEAM run time.
Weight
Empty
Filled with Water
HM506:
8 Ibs.
12 Ibs.
HM509:
8 Ibs.
15 Ibs.
HM512:
9 Ibs.
15 Ibs.
Dimensions
11-1/4 in. Wx 19 in. H x 9 in. D
Operating
Temperature
Range
TrueSTEAM Humidifier: 34°F-104°F (1.1°C-40°C)
Remote Hose/Nozzle:
-50°F-250°F (-46°C-121°C)
Operating
Humidity Range: 0-95% RH, non-condensing
Drain Operation
Automatic
Flush Schedule:
Configurable
to 8, 12, 20, or
30 hours of operational time (heating element active)
Automatic
Flush Cycle Time: Flush cycle takes
approximately
45 minutes to empty the tank completely
Draining Temperature Range: 34°F-212°F (1.1°C-100°C)
Electrical Ratings and Tolerances
Input Ratings
Power Supply: 120VAC +10-15%, 60Hz
- HM506: 840W at 120VAC at full load
- HM509: 1200W at 120VAC at full load
- HM512: 1440W at 120VAC at full load
HM506: 7A, 120VAC
HM509: 10A, 120VAC
HM512: 12A, 120VAC
15A, 120VAC interlock switch
Thermostat/HVAC
power monitor (R to C):
10mA resistive at 24VAC
Field wiring terminals: 18-22 ga. Solid
HVAC power/airflow
monitor: 10 mA resistive at 24 VAC
Output Ratings
Relay output contacts:
- Fan: 1.5A full load, 7.5A locked rotor at 24VAC
- Heat and backup: 15A resistive at 120VAC
Fill Solenoid: 0.1A at 120VAC, 0.5 PF
Drain Solenoid: 0.1A at 120VAC, 0.5PF
Humidistat output contacts:
10mA resistive at 24VAC
Humidistat power supply: 100mA at 24VAC
Standards and Approval Body Requirements
Underwriters
Laboratories: UL998, File no. E185662
Federal Communications
Commission:
Class B
compliance,
File no. YU555
Intended to be used in accordance
with the
National Electrical Code (NEC), ANSI/NFPA 70,
and the rules of the Canadian Electrical Code (CEC),
Part 1, C22.1