Using The Power (On/Standby) Switch; Figure 5-1 Netra X1 Server Power (On/Standby) Switch - Sun Microsystems Netra X1 User Manual

Hide thumbs Also See for Netra X1:
Table of Contents

Advertisement

"To Power On With the Server's Details Registered at a Name Server" on page 25
or
"To Power On Without the Server's Details Registered at a Name Server" on
page 26.

Using the Power (On/Standby) Switch

Caution – The power switch (on the back panel of the Netra X1 server) is not an
On/Off switch, it is an On/Standby switch. It does not isolate the equipment.
The power (On/Standby) switch of the Netra t1 server is a rocker type, momentary
action switch. It controls only low-voltage signals; no high-voltage circuits pass
through it. This means that the main method of connecting or disconnecting power
is by inserting or removing the power supply cord. The server contains no integral
circuit breakers. To isolate it, you must break all connections to it. If you do not do
this by removing the power supply cord, you must instead open all external circuit
breakers.
FIGURE 5-1
The symbols on the switch are:
On
Standby
30
Netra X1 Server User's Guide • December 2000
On / Standby Switch
Netra X1 Server Power (On/Standby) Switch
Press to apply power to the server.
Press for less than four seconds to initiate an orderly shutdown of the system
into Standby mode.

Advertisement