IKEA IH5303SS0 Installation Instructions And Use & Care Manual page 5

90 cm (35 2/5") wall-mount canopy range hood
Table of Contents

Advertisement

Available languages

Available languages

10 3/ld'
(27.5 era)
11%6"
_,-- [
(28.7 cm)
3
15/16"
(10.0cm)
19 J''l/lo"
(5o.? ore)I
!i + TI
31%o" (10.0cm)
Installation Dimensions
,2s12"o , z' (5.1 cm) m in.
_-__ ..... L\
7" (.17.8cm) min. (non-vented
__,.:.
recMrcuJating i nst. ONLY)
10(2 4
Side
cabinet
.................................. ! ............ 19 V_d'
(48.4cm)
I
rnin.
30" (76.2 cm) rain.
I
36" (91.4 cm) max.
',
bottom of canopy to Icenterline
cooking surface
Side
cabinet
Vent system must terminate to the outside, except for non-
vented (recirculating) installations.
Do not terminate the vent system in an attic or other enclosed
area.
Do not use 4" (10.2 cm) laundry-type wall caps.
Use metal vent only. Rigid metal vent is recommended.
Do
not use plastic or metal foil vent.
The vent system must have a damper. If the roof or wall cap
has a damper, do not use the damper supplied with the range
hood.
For the most efficient and quiet operation:
Use a straight run or as few elbows as possible.
Use no more than three 90 ° elbows.
Make sure there is a minimum of 24" (61 cm) of straight vent
between the elbows if more than 1 elbow is used.
Do not install 2 elbows together.
Use clamps to seal all joints in the vent system.
Use caulking to seal exterior wall or roof opening around the
cap.
The size of the vent should be uniform.
Cold weather
installations
An additional
back draft damper should be installed to minimize
backward cold air flow and a nonmetallic
thermal break should
be installed to minimize conduction
of outside temperatures
as
part of the vent system. The damper should be on the cold air
side of the thermal break.
The break should be as close as possible to where the vent
system enters the heated portion of the house.
Makeup
air
Local building codes may require the use of make up air systems
when using ventilation systems greater than specified CFM of air
movement. The specified CFM varies from locale to locale.
Consult your HVAC professional for specific requirements in your
area.
Venting Methods
This canopy hood is factory set for venting through the roof or
wall.
A 6" (15.2 cm) round vent system is needed for installation (not
included). The hood exhaust opening is 6" (15.2 cm) round.
NOTE: Flexible vent is not recommended.
Flexible vent creates
back pressure and air turbulence that greatly reduce
performance.
Vent system can terminate either through the roof or wall. To vent
through a wall, a 90 ° elbow is needed.
Rear discharge
A 90° elbow may be installed immediately above the hood.