IKEA IH4302SS0 Installation Instructions And Use & Care Manual

30"(76.2cm) wall-mount canopy range hood
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

|KEA
®
30"(76.2 CM) WALL-MOUNT CANOPY
RANGE HOOD
HOTTEDE CUISINII:REPOUR MONTAGE MURAL
30" (76,2 CM)
Table of Contents/Table
des matieres .............................................................................
2
IMPORTANT: READ AND SAVETHESE
INSTRUCTIONS.
FOR RESIDENTIAL
USE ONLY.
IMPORTANT : URE ET CONSERVER CES INSTRUCTIONS.
POUR UTILISATION
RESIDENTIELLE
UNIQUEMENT.
IMPORTANT:
Installer:
Leave installation instructions with the homeowner.
Homeowner:
Keep installation instructions for future reference.
Save installation instructions for local electrical inspector's use.
IMPORTANT :
InstaJlateur
: Remettre les instructions d'installation au propri_taire.
Propri_taire : Conserver les instructions d'installation pour r_f@ence ult@ieure.
Conserver les instructions d'installation pour consultation par I'inspecteur local des installations _lectriques.
W10018040A

Advertisement

Table of Contents
loading

Summary of Contents for IKEA IH4302SS0

  • Page 1 |KEA ® 30"(76.2 CM) WALL-MOUNT CANOPY RANGE HOOD HOTTEDE CUISINII:REPOUR MONTAGE MURAL 30" (76,2 CM) Table of Contents/Table des matieres ................IMPORTANT: READ AND SAVETHESE INSTRUCTIONS. FOR RESIDENTIAL USE ONLY. IMPORTANT : URE ET CONSERVER CES INSTRUCTIONS. POUR UTILISATION RESIDENTIELLE UNIQUEMENT.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS TABLEDESMATIERES SECURITE DE LA HOTTE DE CUlSINIERE ....... 15 RANGE HOOD SAFETY ..............INSTALLATION REQUIREMENTS ..........EXIGENCES D'INSTALLATION ........... Tools and Parts ................Outillage et pieces ..............Location Requirements ..............Exigences d'emplacement ............Venting Requirements ..............Exigences concernant I'evacuation ........... 18 Electrical Requirements ...............
  • Page 3 iMPORTANT SAFETY iNSTRUCTiONS WARNING: TO REDUCE THE RISK OF A RANGE TOP WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC GREASE FIRE: SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: [] Never leave the surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may [] Use this unit only in the manner intended by the ignite.
  • Page 4: Installation Requirements

    INSTALLATION REQUIREMENTS Gather the required tools and parts before starting installation. IMPORTANT: Observe all governing codes and ordinances. Read and follow the instructions provided with any tools listed Have a qualified technician install the range hood. It is the here. installer's responsibility to comply with installation clearances specified on the model/serial rating plate.
  • Page 5: Venting Requirements

    The specified CFM varies from locale to locale. Consult your Installation Dimensions HVAC professional for specific requirements in your area. 7" Venting Methods (17.8 era) 2" (5.1 era) rain. This range hood is factory set for venting through the roof or wall. 7"...
  • Page 6: Electrical Requirements

    A copy of the above code standards can be obtained from: Example Vent System National Fire Protection Association One Batterymarch Park ,o ° elbow I-_-_ 6. (_.8m)-_,,_l Wall cap Quincy, MA 02269 CSA International 8501 East Pleasant Valley Road Cleveland, OH 44131-5575 •...
  • Page 7: Install Range Hood

    7. Tape template in place, aligning the template centerline and Drill 3/8"(9.5 mm) holes for wall anchors and insert anchors flush with the wall. bottom of template with hood bottom line and with the centerline marked on the wall. Attach vent cover bracket to wall using 2 - 10 x 60 mm drywall anchors and 2 - 6 x 70 mm screws.
  • Page 8: Make Electrical Connection

    6. Use UL listed wire connectors and connect white wires together. Electrical Shock Hazard Electrical Shock Hazard Electrically ground blower. Disconnect power before servicing. Connect ground wire to green and yellow ground wire Replace all parts and panels before operating. in terminal box.
  • Page 9: Complete Installation

    2. Remove the protective film from the unpainted side of the trim piece. , , ° .." ..;_" ¢,.,_,oFlS.©lesi÷,, Install Vent Covers Push the lower vent cover down onto the range hood and lift the upper vent cover to the ceiling and install 4 - 3 x 9 mm screws...
  • Page 10: Install Filters

    RANGE HOOD USE For non-vented (recirculating) installations, install the charcoal filter over the grille on the blower housing and turn the filter handle clockwise. Repeat with the other charcoal filter. The range hood is designed to remove smoke, cooking vapors and odors from the cooktop area.
  • Page 11 3. Pull filter toward the front. To replace the metal grease filters: 1. Insert back edge of filter into the rear channel of the filter opening. 2. Push handle toward the rear and push filter up. 3. Pull filter toward the front and insert into front channel. Replacing a halogen lamp Turn off the range hood and allow the halogen lamps to cool.
  • Page 12: Wiring Diagram

    WIRING DIAGRAM SLM,SLS SE1L7A 8-10 WIRING 246811 SLM,SLS 1 €_ & >- >- Motor Connections Ohm resistance speed to terminals between terminals red-black bridge:yellow-white red-yellow bridge:yellow-white red-yellow bridge:yellow*black...
  • Page 13: Assistanceor Service

    Please include a daytime phone number in your correspondence. right and work right because they are made with the same precision used to build every new IKEA® appliance. Accessories List To locate factory specified parts in your area, call us or your nearest designated service center.
  • Page 14: Follow

    How to reach us if you need our service If outside the 50 United States and Canada, contact your authorized IKEA retailer to determine if another warranty applies. If you need service, please read the Installation Instructions and/or the "Troubleshooting"...
  • Page 15: Securite De La Hotte De Culsiniere

    SECURITE DE LA HOTTE DECUlSlNIERE Votre securite et celle des autres est tres importante. Nous donnons de nombreux messages de s_curit_ importants dans ce manuel et sur votre appareil m_nager. Assurez-vous toujours lire tous les messages de s_curit_ et de vous y conformer. Ce symbole d'alerte de s_curit_ vous signale les dangers potentiels de d_c_s et de blessures graves &...
  • Page 16 IMPORTANTES iNSTRUCTiONS DE SECURITE AVERTISSEIVIENT : POUR MINIMISER LE RISQUE AVERTISSEIVIENT : POUR REDUIRE LE RISQUE D'UN FEU DE GRAISSE SUR LA CUISINIF:RE : D'INCENDIE, CHOC ¢:LECTRIQUE OU DOMMAGES CORPORELS, RESPECTER LES INSTRUCTIONS [] Ne jamais laisser un 616ment de surface fonctionner &...
  • Page 17: Exigencesd'installation

    EXIGENCESD'INSTALLATION • Gabarit de montage c g® ® • Cache-conduit- 2 pieces Rassembler les outils et pieces necessaires avant de commencer • Garniture I'installation. Lire et suivre les instructions fournies avec les outils • Ruban adhesif indiques ici. • 3 supports de garniture Outillage n_cessaire •...
  • Page 18: Exigences Concernant I'evacuation

    • Utiliser un conduit m6tallique uniquement. Un conduit en Dimensions du produit m6tal rigide est recommand& Ne pas utiliser de conduit de plastique ou de m6tal tr_s mince. • Le systeme d%vacuation dolt comporter un clapet. Si la bouche de decharge murale ou par le toit comporte clapet, ne pas utiliser le clapet fourni avec la hotte de cuisiniere.
  • Page 19 Dans I'exemple suivant, la Iongueur theorique du circuit est Installation sans d_charge & I'ext_rieur (recyclage) inferieure au maximum de 35 pi (10,7 m). S'il n'est pas possible d'evacuer les fumees et vapeurs de cuisson & I'exterieur, on peut employer la version "installation 1 -coudea90 °...
  • Page 20: Instructions D'installation

    INSTRUCTIONS D'INSTALLATION ....,,,,,,..Y [_%_ 1)]1%2 I01' ...._:;A =,_,_. • On recommande que le circuit d'evacuation soit install8 avant 7. Fixer le gabarit en place avec du ruban adh@sif; aligner I'axe I'installation de la hotte, central du gabarit et le bas du gabarit avec la ligne correspondant au bas de la hotte, et avec I'axe central dSji On ne dolt couper un poteau de colombage ou une solive...
  • Page 21: Installation De La Hotte

    Installation de la bride de cache-conduit Installation avec utilisation de t_lescope et des sections sup_rieure et inf_rieure du cache-conduit 1. Positionner la bride de cache-conduit sur lemur a environ 1/8"(3 mm) du plafond. 2. Faire des reperes aux emplacements des trous. 3.
  • Page 22: Raccordement Du Circuit D'evacuation

    5. Connecter ensemble les conducteurs noirs - utiliser un Installation sans d_charge & I'ext_rieur (recyclage) connecteur de fils (homologation UL). 6. Connecter ensemble les conducteurs blancs - utiliser un Installer le deflecteur a I'interieur de la section inferieure du connecteur de fils (homologation UL).
  • Page 23: Installation De La Garniture

    4. Inserer la garniture avec le c6te couvert de ruban adhesif expos& Installer les trois supports de garniture au-dessus de la hotte I'aide de 6 vis de 3 x 9 ram. Ne pas serrer completement vis, pour permettre les reglages eventuels. A.
  • Page 24: Contr61E Du Fonctionnement

    Cone <:t on ' semen 4. Pour commander I'arr_t du ventilateur et I'extinction A ../f" f>0_1 _ ° 1_=_22_23 _ ..B lampes, placer les commutateurs & la position "0". u=j; X... 5. Si la hotte ne fonctionne pas, determiner si un disjoncteur s'est ouvert ou si un fusible est grill&...
  • Page 25 4. Conserver le filtre a part, sur une surface proteg6e (par Filtres & charbon - Installation sans d_charge & I'ext_rieur exemple, protection par une serviette) (recyclage) Les filtres a charbon retiennent les composes responsables 5. Tourner la manette du filtre a charbon dans le sens anti- odeurs de cuisson.
  • Page 26: Schema De C.&,Blage

    SCHI MA DE CABLAGE SLM,SLS ARRET SEIL7A 8-10 BO/TE DE CONNEXION --- L N SLM,SLS Vitesse Broches R_sistance (Ohms) du moteur connexiori eritre les broches rouge-noir con. : jaune-blanc rouge-jaune con. : jaune-blanc rouge-jaune COB. :jaune-noir...
  • Page 27: Assistance Ou Service

    Quels sont les appareils mdnagers non couverts par la garantie limitde IKEA de cinq (5) ans? Pour les gros appareils menagers portant le nom "LAGAN", cette garantie limitee est valide pendant un an & compter de la date d'achat. Qui effectuera...
  • Page 28 Si vous residez & I'exterieur des 50 12tats des 12tats-Unis et du Canada, contactez votre marchand IKEA autorise pour determiner si une autre garantie s'applique. Si vous avez besoin d'une intervention d'entretien ou de reparation, veuillez lire les Instructions...

This manual is also suitable for:

Ih4302ws0

Table of Contents