IKEA IHW8303WS0 Installation Instructions And Use & Care Manual
IKEA IHW8303WS0 Installation Instructions And Use & Care Manual

IKEA IHW8303WS0 Installation Instructions And Use & Care Manual

30"(76.2cm) wall-mount canopy range hood
Hide thumbs Also See for IHW8303WS0:
Table of Contents

Advertisement

Available languages

Available languages

30"(76.2 CM) WALL-MOUNT CANOPY
RANGE HOOD
HOTTEDE CUISINII:REPOUR MONTAGE MURAL
30" (76,2 CM)
Table of Contents/Table
des matieres .............................................................................
2
IMPORTANT:
READ AND SAVE THESE INSTRUCTIONS.
FOR RESIDENTIAL
USE ONLY.
IMPORTANT : LIRE ET CONSERVER CES INSTRUCTIONS.
POUR UTILISATION
RI_SIDENTIELLE
UNIQUEMENT.
W10177449B

Advertisement

Table of Contents
loading

Summary of Contents for IKEA IHW8303WS0

  • Page 1 30"(76.2 CM) WALL-MOUNT CANOPY RANGE HOOD HOTTEDE CUISINII:REPOUR MONTAGE MURAL 30" (76,2 CM) Table of Contents/Table des matieres ................IMPORTANT: READ AND SAVE THESE INSTRUCTIONS. FOR RESIDENTIAL USE ONLY. IMPORTANT : LIRE ET CONSERVER CES INSTRUCTIONS. POUR UTILISATION RI_SIDENTIELLE UNIQUEMENT. W10177449B...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS TABLEDESMATIERES SECURITE DE LA HOTTE DE CUlSINIERE ....... 15 RANGE HOOD SAFETY ..............INSTALLATION REQUIREMENTS ..........EXIGENCES D'INSTALLATION ........... Tools and Parts ................Outillage et pieces ..............Location Requirements ..............Exigences d'emplacement ............Venting Requirements ..............Exigences concernant I'evacuation ........... 18 Electrical Requirements ...............
  • Page 3 iMPORTANT SAFETY iNSTRUCTiONS WARNING: TO REDUCE THE RISK OF A RANGE TOP WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC GREASE FIRE: SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: [] Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may [] Use this unit only in the manner intended by the ignite.
  • Page 4: Installation Requirements

    INSTALLATION REQUIREMENTS • Vent cover bracket (3 pieces, to assemble) • 2-piece vent cover Gather the required tools and parts before starting installation. • Aesthetic cover Read and follow the instructions provided with any tools listed here. Tools needed • Level IMPORTANT: Observe all governing codes and ordinances.
  • Page 5 Makeup Installation Dimensions Local building codes may require the use of makeup air systems when using ventilation systems greater than specified CFM of air movement. 14 IE The specified CFM varies from locale to locale. Consult your (35.6 cm) 2" (5.1 cm) rain. HVAC professional for specific requirements in your area.
  • Page 6: Range Hood Safety

    If codes permit and a separate ground wire is used, it is Example Vent System recommended that a qualified electrician determine that the ground path is adequate. ,o ° elbow I-_-_ 6. (_.8m)-_,,_l Wall cap A copy of the above code standards can be obtained from: National Fire Protection Association One Batterymarch Park...
  • Page 7: Venting Requirements

    Place the lower support bracket on the template aligning it 3. Run wire through the home power supply cable according to the National Electrical Code or CSA Standards and local with the traced rectangle. Mark centers of 3 fastener locations through the template to the wall. codes and ordinances.
  • Page 8 Mc <® Eecff ccl Connect on Vented Installations Only 1. Fit vent system over transition piece. 2. Seal connection with clamps. Non-vented (recirculating} Installation 1. Assemble the 3 parts of the deflector with 2 - 3.5 x 6.5 screws provided. The assembled deflector should be sized to fit the Electrical Shock Hazard width of the vent cover bracket installed earlier.
  • Page 9 5. Tighten the four screws to attach the glass in place. Electrical Shock Hazard Electrically ground blower. Connect ground wire to green and yellow ground wire in terminal box. Failure to do so can result in death or electrical shock. 8.
  • Page 10: Range Hood Use

    For non-vented (recirculating) installations 1. Turn off blower and lights. Check that halogen lamps are _'-_ cool. 2. Remove the metal grease filters by pushing handle toward the rear and pull downward. A. Light button B. Indicator lights C. Speed button 1.
  • Page 11: Range Hood Care

    RANGE HOOD CARE IMPORTANT: Clean the hood and grease filters frequently To Replace Charcoal Filter: according to the following instructions. Replace grease filters 1. Turn off blower and lights. Check that range hood is off and before operating hood. halogen lamp is cool. Check that lights are cool before cleaning the hood.
  • Page 12: Wiring Diagram

    WIRING DIAGRAM User Interface >- >- or" ¢T" <:( rr _ SEIS2A "___ ®_)_ ...O_,-- COLOR TABLE COLOR TABLE BLACK ®__ BLUE WHITE BROWN YELLOW GREEN YELLOW/GREEN GREY...
  • Page 13: Assistanceor Service

    Factory specified parts will fit right and work right because they are made with the same precision used to build every new IKEA® appliance. Charcoal Filter Kit To locate factory specified parts in your area, call us or your nearest designated service center.
  • Page 14: Warranty

    How to reach us if you need our service If outside the 50 United States and Canada, contact your authorized IKEA retailer to determine if another warranty applies. If you need service, please read the Installation Instructions and/or the "Troubleshooting"...
  • Page 15: Securite De La Hotte De Culsiniere

    Keep this book and your sales slip together for future Dealer name reference. You must provide proof of purchase or installation date for in-warranty service. Address Write down the following information about your major appliance Phone number to better help you obtain assistance or service if you ever need it. You will need to know your complete model number and serial Model number number.
  • Page 16 IMPORTANTES iNSTRUCTiONS DE SECURITE AVERTISSEMENT : POUR MINIMISER LE RISQUE AVERTISSEMENT : POUR REDUIRE LE RISQUE D'UN FEU DE GRAISSE SUR LA CUISINIF:RE : D'INCENDIE, CHOC ¢:LECTRIQUE OU DOMMAGES CORPORELS, RESPECTER LES INSTRUCTIONS [] Ne jamais laisser un 616ment de surface fonctionner &...
  • Page 17: Exigencesd'installation

    EXIGENCESD'INSTALLATION • 2visde6x70mm • 6 vis de 3,5 x 6,5 mm Rassembler les outils et pieces necessaires avant de commencer • 2 vis de 2,9 x 6,5 mm I'installation. Lire et suivre les instructions fournies avec les outils • 2 chevilles d'ancrage pour panneaux de gypse de indiques ici.
  • Page 18 • Utiliser un conduit metallique uniquement. Un conduit en Dimensions du produit metal rigide est recommand& Ne pas utiliser de conduit de plastique ou de metal tr_s mince. • Minimiser le plus possible la Iongueur du conduit et le nombre de coudes pour optimiser la performance. Pour un fonctionnement efficace et silencieux : 117/16"(29 crn) rnin.
  • Page 19 Installation sans d_charge _ I'ext_rieur (recyclage) Exemple de syst_me de d_charge S'il n'est pas possible d'evacuer les fumees et vapeurs de Bouche de cuisson & I'exterieur, on peut employer la version "installation Coude _ 90° _-_6 pi (1,8m)-m_'_ I decharge murale sans decharge &...
  • Page 20: Instructions D'installation

    INSTRUCTIONS D'INSTALLATION On recommande que le circuit d'evacuation soit installe avant 8. Placer la bride de support inferieure sur le gabarit; aligner la I'installation de la hotte. bride avec le rectangle trac& Marquer sur lemur a travers le gabarit la position du centre des 3 organes de fixation. Avant d'executer les decoupages, verifier la disponibilite d'un espace de passage suffisant dans le plafond ou le mur pour IMPORTANT...
  • Page 21 Retirer le filtre a graisse metallique; fixer le carter du Derni_res _tapes de la preparation ventilateur avec une vis placee dans le trou du bas, & I'arriere du ventilateur. 1. Determiner et marquer toutes les lignes de decoupage necessaires sur lemur pour le passage du circuit d'evacuation.
  • Page 22 3. Mesurer la Iongueur de conduit de 8" (20,3 cm) necessaire 4. Installer un serre-c&ble (homologation UL ou CSA). pour le raccordement entre le raccord de transition et le deflecteur. REMARQUE • Le conduit d'evacuation dolt _tre inser6 d'au moins 1" (2,5 cm) a I'interieur du deflecteur. 4.
  • Page 23: Installation Des Filtres

    nskxc; ton 1. Contr61er le fonctionnement des lampes et du ventilateur. Voir 5. Serrer les quatre vis pour maintenir le capot en verre en la section "Utilisation de la hotte". place. Si la hotte ne fonctionne pas : • Verifier si le disjoncteur s'est declench6 ou si un fusible est grill&...
  • Page 24: Utilisation De La Hotte

    Installation sans d_charge a I'ext_rieur (recyclage) 1. Commander I'arret du ventilateur et I'extinction des lampes. Verifier que les lampes a halogene sont froides. 2. Retirer les filtres a graisse metalliques - pousser la manette vers I'arriere et tirer vers le bas. A.
  • Page 25: Entretien De La Ho'n'e

    ENTRETIEN D E LA HOTTE IMPORTANT : Nettoyer la hotte et les filtres & graisse Remplacement des filtres & charbon regulierement en suivant les instructions suivantes. Remettre en 1. Commander I'arr_t du ventilateur et I'extinction des lampes. place les filtres & graisse avant de mettre en marche la hotte. Verifier que la hotte est eteinte et que la lampe a halogene est froide.
  • Page 26: Schema De C.&,Blage

    SCHI_MA DE CABLAGE p nterface utilisateur ] Panneau principal I Filtre E.M.C. SEIS2A JA-VE JA-VE =-'_ JA-VE JA-VE °, GRIS TABLEAU DES COULEURS TABLEAU DES COULEURS NOIR ROUGE BLEU BLANC MARRON JAUNE VERT JA-VE JA U N E/V E RT GRIS GRIS...
  • Page 27: Assistance Ou Service

    Quels sont les appareils mdnagers non couverts par la garantie limitde IKEA de cinq (5) ans? Pour les gros appareils menagers portant le nom "LAGAN", cette garantie limitee est valide pendant un an & compter de la date d'achat. Qui effectuera...
  • Page 28 Si vous residez & I'exterieur des 50 12tats des 12tats-Unis et du Canada, contactez votre marchand IKEA autorise pour determiner si une autre garantie s'applique. Si vous avez besoin d'une intervention...

Table of Contents