30" (76.2 cm) wall-mount canopy range hood (30 pages)
Summary of Contents for IKEA IH6242WM0
Page 1
| KEA ® 60 CM (23 %") WALL-MOUNT CANOPY RANGE HOOD HOTTEDE CUlSlNII:RE POUR MONTAGE MURAL 60 CM (23 %") Table of Contents/Table des matieres ................IMPORTANT: READ AND SAVE THESE INSTRUCTIONS. FOR RESIDENTIAL USE ONLY. IMPORTANT : LIRE ET CONSERVER CES INSTRUCTIONS. POUR UTILISATION RESIDENTIELLE UNIQUEMENT.
TABLE OF CONTENTS TABLE DESMATIERES SECURITE DE LA HOTTE DE CUlSINIERE ........ 15 RANGE HOOD SAFETY ..............INSTALLATION REQUIREMENTS ..........EXIGENCES D'INSTALLATION ........... Tools and Parts ................Outillage et pieces ..............Location Requirements ..............Exigences d'emplacement ............Venting Requirements ..............Exigences concernant I'evacuation ...........
Page 3
iMPORTANT SAFETY iNSTRUCTiONS WARNING: TO REDUCE THE RISK OF A RANGE TOP WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC GREASE FIRE: SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: [] Never leave the surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may [] Use this unit only in the manner intended by the ignite.
INSTALLATION REQUIREMENTS Gather the required tools and parts before starting installation. IMPORTANT: Observe all governing codes and ordinances. Read and follow the instructions provided with any tools listed Have a qualified technician install the range hood. It is the here. installer's responsibility to comply with installation clearances specified on the model/serial rating plate.
Page 5
Cold weather installations Installation Dimensions An additional back draft damper should be installed to minimize backward cold air flow and a nonmetallic thermal break should be installed to minimize conduction of outside temperatures part of the vent system. The damper should be on the cold air side of the thermal break.
Page 6
Calculating Vent System Length _,_" _y",_ • IMPORTANT: Observe all governing codes and ordinances. Save To calculate the length of the system you need, add the Installation Instructions for electrical inspector's use. equivalent feet (meters) for each vent piece used in the system. It is the customer's responsibility to contact a qualified electrical Vent Piece...
INSTALLATION INSTRUCTIONS It is recommended that the vent system be installed before Tape template in place, aligning the template centerline and hood is installed. bottom of template with hood bottom line and with the centerline marked on the wall. Do not cut a joist or stud unless absolutely necessary. If a joist or stud must be cut, then a supporting frame must be ==l=...
Page 8
Vent Cover Bracket Installation Installations using telescoping upper and lower vent cover assembly 1. Position vent cover bracket on wall about 1/8"(3 mm) away from the ceiling. 2. Mark the hole locations. 3. Drill 3/8"(9.5 mm) holes for wall anchors and insert anchors flush with the wall.
Page 9
5. Use UL listed wire connectors and connect black wires together. 6. Use UL listed wire connectors and connect white wires @%:v®n"ed ns_J _@w"s o_"t_' together. Fit vent system over transition piece. Electrical Shock Hazard Electrically ground blower. A. Transition Connect ground wire to green and yellow ground wire B.
For non-vented (recirculating installations, install charcoal filter over grille on blower housing and turn filter handle .._ o1_ ®0123 {_ ..clockwise. Repeat with other charcoal filter. A. Light switch B. Blower switch 1. Move the light switch to "1" position. The light should turn on. 2.
RANGE HOOD CARE IMPORTANT: Clean the hood and grease filters frequently To Replace Metal Grease Filters according to the following instructions. Replace grease filters 1. Insert back edge of filter into rear channel of the filter before operating hood. opening. Be sure lights are cool before cleaning the hood.
WIRING DIAGRAM SLM,SLS SE1L7A 8-10 WIRING 8°_ I s' s szJ >- >- > > Motor Connections resistance speed to terminals between terminals red-black bridge:yellow-white red-yellow bridge:yellow*white red-yellow bridge:yellow=black...
Call the Whirlpool Canada LP Customer Interaction Centre toll- precision used to build every new IKEA® appliance. free: 1-866-664-2449. To locate factory specified parts in your area, call us or your...
How to reach us if you need our service If outside the 50 United States and Canada, contact your authorized IKEA retailer to determine if another warranty applies. If you need service, please read the Installation Instructions and/or the "Troubleshooting"...
SECURITE DE LA HOTTE DECUlSlNIERE Votre securite et celle des autres est tres importante. Nous donnons de nombreux messages de s_curit_ importants dans ce manuel et sur votre appareil m_nager. Assurez-vous toujours lire tousles messages de s_curit_ et de vous y conformer. Ce symbole d'alerte de s_curit_ vous signale les dangers potentiels de d_c_s et de blessures graves &...
Page 16
IMPORTANTES iNSTRUCTiONS DE SECURITE AVERTISSEMENT : POUR MINIMISER LE RISQUE AVERTISSEMENT : POUR Rt_DUIRE LE RISQUE D'UN FEU DE GRAISSE SUR LA CUISINIF:RE : D'INCENDIE, CHOC ¢:LECTRIQUE OU DOMMAGES CORPORELS, RESPECTER LES INSTRUCTIONS [] Ne jamais laisser un 616ment de surface fonctionner &...
EXIGENCESD'INSTALLATION • 2 crochets de montage • Bride de support du cache-conduit Rassembler les outils et pieces necessaJres avant de commencer • Gabarit de montage I'installation. Lire et suivre les instructions fournies avec les outils • Cache-conduit- 2 pieces indiqu6s ici. •...
Page 18
Le systeme d'evacuation doit comporter un clapet. Si la Dimensions du produit bouche de decharge murale ou par le toit comporte clapet, ne pas utiliser le clapet fourni avec la hotte de cuisiniere. 613/16" 81/5. (17,3 cm) crn) Pour un fonctionnement efficace et silencieux : •...
Page 19
Installation sans D_charge D_charge travers le toit travers le mur d_charge I'ext_rieur (recyclage) IMPORTANT : Observer les dispositions de tous les codes et reglements en vigueur. Conserver les instructions d'installation pour consultation par I'inspecteur des installations electriques. C'est au client qu'incombe la responsabilite de contacter un electricien qualifie et de veiller &...
INSTRUCTIONS D'INSTALLATION On recommande que le circuit d'evacuation s oit installe avant ==1= l'installation de lahotte. On ne dolt couper un poteau de colombage ou une solive que si c'est absolument necessaire. Dans ce cas, on devra construire une structure de support appropriee..
Page 21
Installation de la bride de cache-conduit Installation avec utilisation de t_lescope et des sections sup_rieure et inf_rieure du cache-conduit 1. Positionner la bride de cache-conduit sur lemur a environ 1/8"(3 mm) du plafond. 2. Faire des reperes aux emplacements des trous. 3.
Page 22
Acheminer 3 conducteurs de calibre 14 (noir, blanc et vert) dans un conduit de _/_"entre le tableau de distribution et la bofte de connexion. Connecter le circuit d'evacuation sur le raccord de transition. j¢ A. Raccord de transition A. Serre-c#ble (homologation UL ou CSA) B.
Page 23
2. Pour tous les types d'installations, inserer le bord arriere ou le filtre metallique dans la rainure arriere de I'ouverture du filtre. 3. Pousser la manette vers I'arriere et pousser le filtre vers le 1. Installer le cache-conduit. haut. En cas d'utilisation des sections superieure et inferieure 4.
UTILISATION DE LA HOTTE La hotte est congue pour extraire fumee, vapeurs de cuisson et Commande de la lampe odeurs au-dessus de la table de cuisson. Pour obtenir les 1. Placer le commutateur d'eclairage & la position "1" pour meilleurs resultats, mettre le ventilateur de la hotte en marche commander la mise en marche de la lampe.
Installation des filtres & charbon Remplacement d'une lampe & halog_ne 1. Commander I'arr_t du ventilateur et I'extinction des lampes. Interrompre I'alimentation de la hotte; attendre le refroidissement Verifier que la lampe a halogene est froide. de la lampe a halogene. Utiliser un chiffon pour le remplacement. 2.
Quels sont les appareils m_nagers non couverts par la garantie limit_e IKEA de cinq (5) ans? Pour les gros appareils menagers portant le nom "LAGAN", cette garantie limitee est valide pendant un an & compter de la date d'achat. Qui effectuera...
Page 28
Si vous residez & I'exterieur des 50 €:tats des €:tats-Unis et du Canada, contactez votre marchand IKEA autorise pour determiner si une autre garantie s'applique. Si vous avez besoin d'une intervention d'entretien...