  • Page 1 MAC 101 RGB, CT, WRM and CLD models User manual MAC 101 MAC 101 CT MAC 101 CLD MAC 101 WRM...
  • Page 2: Dimensions

    The Martin logo, the Martin name and all other trademarks in this document pertaining to services or products by Martin Professional A/S or its affiliates and subsidiaries are trade- marks owned or licensed by Martin Professional A/S or its affiliates or subsidiaries.
  • Page 3: Safety Information

    If you have questions about how to operate the fixture safely, please contact your Martin supplier or call the Martin 24-hour service hotline on +45 8740 0000, or in the USA on 1-888-tech-180.
  • Page 4 • Refer any service operation not described in this manual to a qualified technician. • Socket outlets used to supply MAC 101 fixtures with power or external power switches must be located near the fixtures and easily accessible so that the fixtures can easily be disconnected from power.
  • Page 5: Table Of Contents

    MAC 101 CLD and MAC 101 WRM DMX protocol ....... .
  • Page 6: Fixture Overview

    Fixture overview Display Control buttons AC mains power input AC mains power throughput Safety cable attachment point DMX output DMX input Figure 1: Fixture overview MAC 101 user manual...
  • Page 7: Introduction

    Introduction Thank you for selecting the MAC 101™, an intelligent lighting fixture from Martin Professional™. This range of compact LED-based moving-head washlight includes four models: All MAC 101 fixtures feature: • DMX control • Onboard control panel and backlit LCD graphic display •...
  • Page 8: Ac Power

    The MAC 101 can be hard-wired to a building electrical installation if you want to install it permanently, or a power plug that is suitable for the local power outlets can be installed on the power cable.
  • Page 9: Relaying Power To Other Devices

    • No matter what the AC mains power voltage is, do not connect more than ten MAC 101 fixtures in total (i.e. including the first fixture) to AC mains power in one interconnected daisy chain using power input and throughput connectors.
  • Page 10: Data Link

    A DMX 512 data link is required in order to control a MAC 101 via DMX. The MAC 101 has 5-pin XLR connectors for DMX data input and output. The pin-out on all connectors is pin 1 = shield, pin 2 = cold (-), and pin 3 = hot (+). Pins 4 and 5 in the 5-pin XLR connectors are not used in the MAC 101 but are available for possible additional data signals as required by the DMX512-A standard.
  • Page 11: Physical Installation

    Physical installation The MAC 101 can be placed on a horizontal surface such as a stage or clamped to a truss in any orientation using a rigging clamp. Warning! Attach an approved safety cable to one of the safety cable attachment points on the base (see “Fixture overview”...
  • Page 12: Hanging The Fixture

    Quick-mount surface mounting brackets (P/N 91606017) for the MAC 101 are available from Martin in sets of 5 brackets. The bracket can be screwed to a surface and the MAC 101 mounted on and removed from the bracket in seconds. Installation instructions are supplied with the brackets.
  • Page 13: Setup

    (Up) forces the fixture to reset. Display panel functions The DMX address is shown in the display panel when the MAC 101 is powered on and has reset. The display panel backlighting indicates fixture status as follows: • The display dims to zero during resets.
  • Page 14: Tailoring Performance

    It is recommended when the MAC 101 is used intensively in a warm environment or in fixed installations. Note that it will give increased fan noise compared to the other cooling modes.
  • Page 15: Restoring Factory Default Settings

    Restoring factory default settings → FACTORY DEFAULT LOAD The MAC 101 factory default settings can be restored by applying a command. Setup...
  • Page 16: Operation And Effects

    22 for a full list of the DMX channels and values required to control the different effects. Pan and tilt The MAC 101’s moving head can be panned through 540° and tilted through 240°. The speed of pan/tilt movement can be adjusted via the control panel.
  • Page 17 DMX values across multiple fixtures. Controlling warm or cold white (MAC 101 WRM and CLD only) Fixture intensity in the MAC 101 WRM and CLD models can be controlled by DMX. Operation and effects...
  • Page 18: Service And Maintenance

    The user will need to clean the MAC 101 periodically, and it is also possible for the user to update the firmware and install the optional diffuser accessory available from Martin. All other service operations on the MAC 101 must be carried out by Martin Professional or its approved service agents.
  • Page 19: Control Menu Service Utilities

    Pan and tilt calibration Pan and tilt on the MAC 101 are calibrated at the factory so that movement is identical in multiple fixtures. Adjustment should not be necessary initially, but over a period of use fixtures may gradually lose calibration.
  • Page 20: Fixture Readouts

    Software upload The MAC 101 is loaded with both software (that can be installed and updated by the user) and firmware (that is internal and accessible to Martin Service and its authorized partners only). Software updates are available from the Martin website and can be installed with a PC and Martin USB Duo DMX Interface box that can upload software to one fixture at a time.
  • Page 21: Installing Optional Diffuser Filters

    Installing optional diffuser filters A set of eight medium-angle diffuser filters can be ordered from Martin (P/N 91616018) as an optional accessory for the MAC 101. A diffuser filter softens the output from the LEDs and provides a wider beam angle.
  • Page 22: Dmx Protocols

    DMX protocols Standard MAC 101 RGB DMX protocol Raw, RGB Basic DMX Value Percent Function Electronic shutter effect 0 - 19 0 - 7 Shutter closed 20 - 49 8 - 19 Shutter open Strobe 1 (fast → slow) 50 - 64...
  • Page 23 CTC 10 000K → 2 500K 20 - 255 8 - 100 Table 2: MAC 101 DMX Protocol Note: DMX values labeled "No function" will have no effect - the last functional value will be used. mode, RGB output is uncalibrated. In...
  • Page 24: Mac 101 Ct Dmx Protocol

    0 - 255 0 - 100 Color Temperature Control 0 - 19 0 - 7 No Function Color temperature, calibrated, 6200 → 2800 K 20 - 255 8 - 100 Table 3: MAC 101 CT DMX Protocol MAC 101 user manual...
  • Page 25: Mac 101 Cld And Mac 101 Wrm Dmx Protocol

    MAC 101 CLD and MAC 101 WRM DMX protocol Channel DMX Value Percent Function Electronic shutter effect 0 - 19 0 - 7 Shutter closed 20 - 49 8 - 19 Shutter open Strobe 1 (fast → slow) 50 - 64...
  • Page 26: Lee Colors And Rgb Equivalents

    LEE colors and RGB equivalents The table below gives approximate RGB equivalents for the LEE colors available in the standard MAC 101’s color wheel effect (DMX channel 9). DMX Integer Lee no. Name Green Blue Moroccan Pink Pink Special rose Pink...
  • Page 27: Onboard Control Menus

    Onboard control menus Menu Item Options Notes (Default settings in bold print) DMX address (default address = 1). The DMX address DMX ADDRESS 1 – XXX range is limited so that the fixture will always have enough DMX channels in the 512 available. RGB uncalibrated DMX control mode CONT MODE RGB calibrated DMX control mode...
  • Page 28 CALIBRATION TILT OFFSET Tilt calibration Table 5: Control menu Standard MAC 101 only, shown in menu in all DMX control modes. Standard MAC 101 only, shown in menu when fixture is set to DMX control modes MAC 101 CT only...
  • Page 29: Display Messages

    ...there is a malfunction in the optical pan/tilt FBEP - PAN FBACK ERR monitoring circuit (e.g. sensor defective). After Reset fixture. Contact Martin service if a time-out, the effect in question stops in a problem continues. FBET - TILT FBACK ERR random position.
  • Page 30: Troubleshooting

    Probable cause(s) Remedy No power to fixture. Check AC mains power and connections. Fixture is completely dead. Have faulty fixture serviced by Martin service Internal circuit fault. technician. Inspect connections and cables. Correct poor Fault on data link. connections. Repair or replace damaged cables.
  • Page 31: Specifications

    DMX channels ..............10 MAC 101 WRM and MAC 101 CLD DMX channels .
  • Page 32 Firmware update ....... . .
  • Page 33 Set of 8 x medium-angle diffusers for MAC 101 ....... .
  • Page 34 Equipment), as amended by Directive 2003/108/EC, where applicable. Help preserve the environment! Ensure that this product is recycled at the end of its life. Your supplier can give details of local arrangements for the disposal of Martin products. MAC 101 user manual...
  • Page 36 • • • www.martin.com Olof Palmes Allé 18 8200 Aarhus N Denmark Tel: +45 8740 0000 • Fax +45 8740 0010...

This manual is also suitable for:

Mac 101 cldMac 101 ctMac 101 wrm

Table of Contents