Kenmore 110C66012011 Installation Instructions Manual page 6

27" wide gas & electric dryer

Advertisement

Available languages

Available languages

Location
Requirements
Explosion
Hazard
Keep flammable
materials
and vapors, such as
gasoline, away from dryer.
Place dryer at least 18 inches (460 mm) above the floor
for a garage installation.
Failure to do so can result in death, explosion,
or fire.
You will need:
[]
A location allowing for proper exhaust installation.
See "Venting Requirements."
[]
A separate 30 amp circuit for electric dryers.
[]
A separate 15 or 20 amp circuit for gas dryers.
[]
If you are using power supply cord, a grounded electrical
outlet located within 2 ft. (610 mm) of either side of dryer.
See "Electrical Requirements."
[]
A sturdy floor to support dryer and a total weight (dryer
and load) of 200 Ibs. (90.7 kg). The combined weight of a
companion
appliance should also be considered.
[]
Level floor with maximum slope of 1" (25 mm) under entire
dryer. If slope is greater than 1" (25 mm), install Extended
Dryer Feet Kit, Part Number 279810. If not level, clothes
may not tumble properly and automatic sensor cycles may
not operate correctly.
Do not operate your dryer at temperatures
below 45°F (7°C).
At lower temperatures,
the dryer might not shut off at the end
of an automatic cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it
will be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.
NOTE: No other fuel-burning
appliance can be installed in the
same closet as a dryer.
installation
clearances:
The location must be large enough to allow the dryer door to
open fully.
Most installations require a minimum 51/2"(140 mm) clearance
behind the dryer for the exhaust vent with elbow. See "Venting
Requirements."
Dryer Dimensions
i
m)
m
I
Ill
Yll 133A"
(749 rnrn) X _7"
"\
(749 ram) \
,%J:_f_
27"
-'"
A
B
A. Large opening side-swing
door
B. Wide opening hamper door
installation
Spacing
1"-_1_ 27"_1_ 1"
¢5mrn)
--
_
(310cm) 2
_
24i_
-Hi" F 2_/,,, Hs,/_"*F-
(686rnm)(25turn) (25mm} (743mm}
(140rnm}
A
B
#
C
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
*Required spacing
311,
(76 ram}
(76 rnm)
installation
spacing
for recessed
area or closet
The dimensions shown are for the minimum spacing allowed.
[]
Additional spacing should be considered for ease of
installation and servicing.
[]
Additional clearances might be required for wall, door, and
floor moldings.
[]
Additional spacing of 1" (25 mm) on all sides of the dryer is
recommended
to reduce noise transfer.
[]
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
[]
Companion appliance spacing should also be considered.
Mobile
home
= Additional
installation
requirements
This dryer is suitable for mobile home installations. The
installation must conform to the Manufactured
Home
Construction
and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction
and
Safety, Title 24, HUD Part 280) or the Canadian Manufactured
Home Standard CAN/CSA-Z240
MH.
[]
Metal exhaust system hardware, available for purchase.
For further information, please reference the "Assistance
or
Service" section of the "Dryer User Instructions."
[]
Special provisions must be made in mobile homes to
introduce outside air into the dryer. The opening (such as a
nearby window) should be at least twice as large as the dryer
exhaust opening.
6