Kenmore 27" Installation Instructions Manual page 5

27" wide electric models
Hide thumbs Also See for 27":

Advertisement

Available languages

Available languages

Installation Spacing
_
_=_in._
(310cm) 2
24in=
* _
(l cml
1"_ I_ 27"_ _ 1" -HI"*I<2_/,,, _15,J2,,*_
(25ram) (686mm) (25mm)(25mm)
(743mm}
(140ram)
A
B
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
*Additional
spacing
is recommended.
_f
3 I1.
-_6mm)
(76mm)
-T
Mobile
home
= Additional
installation
requirements
This dryer is suitable for mobile home installations. The
installation must conform to the Manufactured
Home
Construction
and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction
and
Safety, Title 24, HUD Part 280) or the Canadian Manufactured
Home Standard CAN/CSA-Z240
MH.
[]
Metal exhaust system hardware, available for purchase.
For further information, please reference the "Assistance
or
Service" section of the "Dryer User Instructions."
[]
Special provisions must be made in mobile homes to
introduce outside air into the dryer. The opening (such as a
nearby window) should be at least twice as large as the dryer
exhaust opening.
E(ectdca(
Requirements
it is your responsibility:
[]
To contact a qualified electrical installer.
[]
To be sure that the electrical connection is adequate and in
conformance
with the National Electrical Code, ANSI/NFPA
70-latest edition and all local codes and ordinances.
The National Electrical Code requires a 4-wire power supply
connection for homes built after 1996, dryer circuits involved
in remodeling
after 1996, and all mobile home installations.
A copy of the above code standards can be obtained from:
National Fire Protection Association,
One Batterymarch
Park,
Quincy, MA 02269.
[]
To supply the required 3 or 4 wire, single phase, 120/240 volt,
60 Hz, AC only electrical supply (or 3 or 4 wire, 120/208 volt
electrical supply, if specified on the serial/rating
plate) on a
separate 30-amp circuit, fused on both sides of the line. A
time-delay fuse or circuit breaker is recommended.
Connect
to an individual branch circuit. Do not have a fuse in the
neutral or grounding circuit.
[]
Do not use an extension cord.
[]
If codes permit and a separate ground wire is used, it is
recommended
that a qualified electrician determine that the
ground path is adequate.
Electrical
Connection
To properly install your dryer, you must determine the type of
electrical connection you will be using and follow the instructions
provided for it here.
[]
If local codes do not permit the connection of a neutral
ground wire to the neutral wire, see "Optional 3-wire
connection"
section.
[]
This dryer is manufactured
ready to install with a 3-wire
electrical supply connection. The neutral ground wire is
permanently connected to the neutral conductor
(white wire)
within the dryer. If the dryer is installed with a 4-wire electrical
supply connection,
the neutral ground wire must be removed
from the external ground connector screw (green screw), and
secured under the neutral terminal (center or white wire) of
the terminal block. When the neutral ground wire is secured
under the neutral terminal (center or white wire) of the
terminal block, the dryer cabinet is isolated from the neutral
conductor.
[]
A 4-wire power supply connection must be used when the
dryer is installed in a location where grounding through
the neutral conductor
is prohibited.
Grounding through the
neutral is prohibited for (1) new branch-circuit
installations,
(2) mobile homes, (3) recreational vehicles, and (4) areas
where local codes prohibit grounding through the neutral
conductors.
If using a power supply cord:
Use a UL listed power supply cord kit marked for use with
clothes dryers. The kit should contain:
[]
A UL listed 30-amp power supply cord, rated 120/240 volt
minimum. The cord should be type SRD or SRDT and be
at least 4 ft. (1.22 m) long. The wires that connect to the
dryer must end in ring terminals or spade terminals with
upturned ends.
[]
A UL listed strain relief.
if your outlet looks like this:
4-wire receptacle
(14-30R)
Then choose a 4-wire power supply cord
with ring or spade terminals and UL listed
strain relief. The 4-wire power supply cord,
at least 4 ft. (1.22 m) long, must have
4 10-gauge solid copper wires and match
a 4-wire receptacle of NEMA Type 14-30 R.
The ground wire (ground conductor) may be
either green or bare. The neutral conductor
must be identified by a white cover.
If your outlet looks like this:
3-wire
receptacle
(10-30R)
Then choose a 3-wire power supply cord with
ring or spade terminals and UL listed strain
relief. The 3-wire power supply cord, at least
4 ft. (1.22 m) long, must have 3 10-gauge solid
copper wires and match a 3-wire receptacle of
NEMA Type 10-30R.
If connecting
by direct wire:
Power supply cable must match power supply (4-wire or 3-wire)
and be:
[]
Flexible armored cable or nonmetallic
sheathed copper cable
(with ground wire), covered with flexible metallic conduit. All
current-carrying
wires must be insulated.
[]
10-gauge solid copper wire (do not use aluminum).
[]
At least 5 ft. (1.52 m) long.