Download Print this page

Kenmore 27" Installation Instructions Manual page 12

27" wide electric models
Hide thumbs Also See for 27":

Advertisement

Available languages

Available languages

_4,
Connect
neutral
wire
Place hooked end of neutral wire (white or cente) (C) of direct
wire cable under center terminal block screw (B). Squeeze
hooked end together. Tighten screw.
Connect
neutral ground
wire
and neutral wire
Connect neutral ground wire (E) and neutral wire (white or
center wire) (C) of power supply cord or cable under center
terminal block screw (B). Tighten screw.
Place hooked ends of remaining direct wire cable wires
under outer terminal block screws (hooks facing right).
Squeeze hooked ends together and tighten screws. Finally,
reinsert tab of terminal block cover into slot of dryer rear
panel. Secure cover with hold-down
screw. Now, go to
Venting Requirements.
Optionam 3owire Connection
You must
verify with a qualified
electrician
that
this
grounding
method
is acceptable
before
connecting.
Place hooked ends of remaining wires under outer terminal
block screws (hooks facing right). Tighten screws.
Remove center terminal block screw (B). Remove neutral
ground wire (E) from external ground conductor screw (A).
Connect a separate copper ground wire (G) from the external
ground conductor
screw (A) to an adequate ground. Finally,
reinsert tab of terminal block cover into slot of dryer rear
panel. Secure cover with hold-down
screw. Now, go to
Venting Requirements.
12

Advertisement

loading