3-8 Setting Up Your Server

Installation Procedure for NEC Rack/Third Vendor's Rack

This server can be installed in either the NEC rack or a third vendor's rack. Take the following
procedure to install the server in the rack:
Removing the Rail Assemblies
Remove the sliding rails from the server.
Hold the rails and slowly slides them toward the rear of the server until a "click" is heard. The
click indicates that the rails are locked.
Push the release levers on the right and left sides of the server, and remove the rail assemblies from
the server while unlocking.
Only the inner rails remain screwed to the server when the rail assemblies have been removed.
IMPORTANT:
inner rails later. To install each rail assembly on the correct inner rail,
make a mark on the assemblies. Similarly, when installing more than
one server, distinguish between the pairs of inner rails and rail
assemblies of the servers by making marks.
The removed rail assemblies are to be installed on the
Inner rails