Indicator
Fault
Slow Blink (1x per second)
Fast Blink (3x per second)
On
Clean
Slow Blink (1x per second)
Medium Blink (2x per second)
On
Media
Slow Blink (1x per second)
On
Tandberg Data
Table 3 describes what each front panel indicator means.
Activity
Table 3: Fault/Clean/Media LED Activity and Drive Status
See Chapter 4, Troubleshooting, for more details on error
conditions.
3.2.2

Unload/Eject Button Features

The Unload/Eject button provides features in addition to
unloading and ejecting a cartridge. To activate one of these
features, press and hold the Unload/Eject button for the
amount of time specified in Table 4. Release the Unload/Eject
button when the desired LED sequence is displayed.
If you do nothing for 15 seconds after accessing any of the
additional features that require an action, such as loading a
cartridge, the drive returns to normal operating mode.
Note: The Unload/Eject button features indicated by an
asterisk (*) in Table 4 overwrite all data on the cartridge loaded
in the drive. Use extreme caution when accessing these
features to avoid loss of important data.
3-4
Tandberg DLT VS160 Installation and Operations Manual
Using Your Tandberg DLT VS160 Drive
Operating Condition
User initiated write/read diagnostic failed
Servo or mechanism error
Internal firmware error
Calibration error or permanent write/read error
Cleaning in progress
Cleaning required: 250 tape motion hours
exceeded since last cleaning
Unsupported format, or damaged or unsupported
cartridge type inserted into drive
DLT1 (VS80) format DLTtape™ IV cartridge
loaded