7.5.2
SCPI Command subsystem
ABORt
FETCh
:CURRent?
:VOLTage?
MEASure
:CURRent?
:VOLTage?
MEMory
<NR1 | ? >
:VSET <NRf | ? >
:ISET <NRf | ? >
:SAVE
OUTput
<Boolean >
?
:LIMit
:VOLTage <NRf | ? >
:CURRent <NRf | ? >
:STATe?
:PROTection
:CLEar
PROGram
<NR1 | ? >
Abort the Output Action
Fetch Subsystem
Return the fetched output current
Return the fetched output voltage
Measure subsystem
Return the measured output current
Return the measured output voltage
Memory Subsystem
select or return memory number, range
from 0 ~ 9
set or return voltage:0~36V/0~60V
set or return current:0~40A/0~24A
store memory subsystem parameters
Output Subsystem
enable or disable output action
return output state
set or return voltage limit value
set or return current limit value
Return output mode (CV or CC)
Reset latched protection
Program Subsystem
select or return memory number, range
from 1 ~ 10
64