Fault Finding - Blue Seal Evolution GP514 Installation And Operation Manual

Evolution series gas griddle
Table of Contents

Advertisement

Fault Finding

This section provides an easy reference guide to the more common problems that may occur during
operation of your equipment. The fault finding guide in this section is intended to help you correct, or at
least accurately diagnose problems with your equipment.
Although this section covers the most common problems reported, you may encounter a problem not
covered in this section. In such instances, please contact your local authorised service agent who will
make every effort to help you identify and resolve the problem. Please note that the service agent will
require the following information:-
 Model Trade Name and Serial Number of Appliance. (both can be found on Technical Data
Plate located on appliance. (Refer to 'Dimensions' section).
Fault
Pilot will not light.
Pilot goes out when gas control
knob released.
Main burner will not light.
NOTE: Components having adjustments protected (e.g. paint sealed) by manufacturer, are only to
be adjusted by an authorised service agent. They are not to be adjusted by an unqualified
service person.
For Refrigeration Cabinet Fault Finding details, refer to Refrigeration Cabinet Installation and
Operation Manual supplied with appliance.
Possible Cause
No gas supply.
Blocked pilot injector.
Releasing knob before
thermocouple has heated.
Pilot flame too small.
- Gas pressure too low.
- Partially blocked pilot injector.
Thermocouple faulty.
Incorrect supply pressure.
Faulty gas control.
18
Remedy
Ensure gas isolation valve is
turned 'On', and bottles are not
empty.
Call service provider.
Hold knob in for at least 20
seconds following ignition of
pilot.
Call service provider.
Call service provider.
Call service provider.
Call service provider.